United States of
America
OCCUPATIONAL
SAFETY AND HEALTH REVIEW COMMISSION
1924 Building - Room 2R90, 100 Alabama Street, S.W.
Atlanta, Georgia 30303-3104
Secretary
of Labor, |
|
Complainant |
|
v. |
OSHRC Docket No.: 16-0931 &
16-0932 |
Trinity
Marine Products, Inc., |
|
Respondent. |
|
Appearances:
Thomas J. Motzny, Esq., U.S.
Department of Labor, Office of the Solicitor, Nashville,
Tennessee
For the Secretary
McCord
Wilson, Esq., Rader & Campbell, P.C.
For the Respondent
BEFORE: Administrative Law Judge Heather A. Joys
DECISION
AND ORDER
Trinity Marine Products, Inc., (Trinity)
operates a barge building facility in Ashland City, Tennessee. In October of 2015, the Occupational Safety
and Health Administration inspected Trinity’s facility and conducted personnel
monitoring for noise and welding fumes.
As a result of the inspection, on April 6, 2015, the Secretary issued
two citations to Trinity, one alleging violations of OSHA’s safety standards (which
the Commission later docketed as Docket No. 16-0931) and the other alleging
violations of OSHA’s health standards (docketed as Docket No. 16-0932). Trinity timely contested the citations. I consolidated the cases by order issued
November 18, 2016.
Prior to the hearing in this
proceeding, the parties settled all items alleged by the Secretary under Docket
No. 16-0931 and all but Items 2a and 2b under Docket No. 16-0932. (Stipulation of Partial Settlement and Motion
to Withdraw Notice of Contest with Regard to Settled Items).[1]
The remaining items at issue, Item
2a and Item 2b, allege serious violations of 29 C.F.R. §§ 1915.1000(d)(1)(i)
and (2)(i), for exposing employees to an accumulation of air contaminants in
excess of the exposure limits set out in Subpart Z of OSHA’s standards. The Secretary proposes a grouped penalty of
$5,000.00 for Items 2a and 2b.
I held a hearing in this matter on
August 9 and 10, 2017, in Nashville, Tennessee.
The parties filed briefs on October 27, 2017. For the reasons that follow, I VACATE Items 2a and 2b. No penalty is assessed.
BACKGROUND
OSHA Compliance Safety and Health
Officer (CSHO) James Provins worked at OSHA’s Nashville, Tennessee, area office
in 2015 (he has since left OSHA for a position in the private sector) (Tr.
15). CSHO Provins stated the Nashville
area office has “a listing of federal sites and maritime sites that we're
responsible for through the state of Tennessee and Kentucky. The Area Director prepares a list of the
sites that we will inspect each year and [Trinity’s facility] was one of the
ones that was on the list to be inspected for [2015].” (Tr. 18-19) CSHO Provins conducted the health portion of
the health and safety inspection. After
his first day at the facility in October of 2015, he determined sampling for
noise and welding fumes was indicated, and he returned a few days later to
conduct the sampling (Tr. 19-20).[2]
The day of the sampling, CSHO
Provins calibrated small volume air pumps and placed them on three employees
selected by Trinity (Exh. C-1; Tr. 21-22).
He explained how the sampling was conducted:
[The employees] would place the pump on their belt[s],
it's got a tube or a hose that the sample media connects to that comes up
around their back. And it's attached to the shoulder. In welding processes we
try to get it inside the hood so that when the hood comes down it's mimicking or
actually sampling their breathing zone issues. And then that's set on the employees for the
shift, for the day. And then collected at the end of the day and
post-calibrated.
(Tr.
22)
The three employees worked in the
“bottoms” area of the facility, shown in Exhibits C-1 through C-4 (Tr.
27). CSHO Provins sampled the employees
for approximately eight hours (Tr. 33).
He explained that the eight-hour time period is
the
sampling protocol that was dictated to me by the Salt Lake City laboratory
[i.e., OSHA’s Salt Lake Technical Center (SLTC),] when I conferred with them on
collecting the samples for this particular work task under the sample methodology.
The exposure limits established for the different metals for welding is based
on an eight-hour work shift. . . .At the end of the day when the employees were
done, I basically collected the pumps from them and explained to them what
would happen with – the samples at that point would be processed and sent to Salt
Lake for analysis. … I took the samples back to the Nashville Area Office where
I processed the paperwork into the computer, put tape on the sample cassette
itself and then packaged them and shipped them to Salt Lake overnight for
analysis.
(Tr. 33-34)
The
results from the SLTC of each of the sampled employees showed overexposures to
air contaminants listed in Subpart Z (as set out in the instances listed in the
AVDs of Items 2a and 2b) (Exhs. C-6, C-7, C-8; Tr. 35-41). Based on these results, CSHO Provins
recommended the Secretary issue the Citation alleging violations of OSHA’s
health standards, docketed as Docket No. 16-0932. Items 2a and 2b of the Citation remain at
issue.
JURISDICTION
AND COVERAGE
Trinity timely contested the Citation and
Notification of Penalty on April 29, 2016.
The parties stipulate the Commission has jurisdiction over this action
and Trinity is a covered business under the Act (Joint Prehearing Statement, p. 4).
Based on the stipulations and the record evidence, I find the Commission
has jurisdiction over this proceeding under § 10(c) of the Act and Trinity is a
covered employer under § 3(5) of the Act.
THE
CITATION
Items
2a and 2b: Alleged Serious Violations of
§ 1915.1000(d)(1)(i) and (2)(i)
Item 2a:
1915.1000(d)(1)(i)
Item 2a of the Citation alleges,
a) On or about October
25, 2015, at the Trinity Marine facility located at 1050 Trinity Rd, Ashland
City, TN, an employee was welding steel plates and was exposed to an 8 hour
Time Weighted Average concentration of 11.1140 mg/m3 of zinc oxide which is 2 times
the permissible exposure limit of 5 mg/m3.
The sample was taken over 462 minutes and zero exposure was assumed for
the remaining 18 minutes.
b) On or about October
25, 2015, at the Trinity Marine facility located at 1050 Trinity Rd, Ashland
City, TN, an employee was welding steel plates, in the Bottoms Sections, and
was exposed to an 8 hour Time Weighted Average concentration of Particulates
Not Otherwise Regulated (Total Dust) at an 8 hour calculated Time Weighted
Average (TWA) of 16.9210 milligrams grams per cubic meter of air which is 1.128
times the 8 hour time weighted average PEL of 15.0 milligrams per cubic meter
of air.
c) On or about October
25, 2015, at the Trinity Marine facility located at 1050 Trinity Rd, Ashland
City, TN, an employee was welding steel plates, in the Bows and sterns Section,
and was exposed to an 8 hour Time Weighted Average of Particulates Not
Otherwise Regulated (Total Dust) at an 8
hour calculated Time Weighted Average (TWA) of 22.2490 milligrams grams per
cubic meter of air which is 1.483 times the 8 hour time weighted average PEL of
15.0 milligrams per cubic meter of air.
Section
1915.1000(d)(1)(i) provides:
The cumulative exposure
for an 8-hour work shift shall be computed as follows:
E = (Ca Ta+CbTb+...Cn Tn)
÷ 8
Where:
E is the equivalent exposure for the working
shift.
C is the concentration during any period of time
T where the concentration remains constant.
T is the duration in hours of the exposure at
the concentration C.
The value of E shall not exceed the 8-hour time
weighted average specified in subpart Z of 29 CFR part 1915 for the material
involved
Item 2b: 1915.1000(d)(2)(i)
Item 2b of the Citation
alleges,
On or about October 25,
2015, at the Trinity Marine facility located at 1050 Trinity Rd, Ashland City,
TN, an employee was welding and was exposed to an 8 hour Time Weighted Average
concentration of 11.1140 mg/m3 of zinc oxide and 0.057 mg/m3 of copper. Inputting these results into the mixture formula
gives a value of E(m) greater than 1 indicating overexposure.
Section
1915.1000(d)(2)(i) provides:
In case of a mixture of air contaminants an employer shall
compute the equivalent exposure as follows:
Em = (C1 ÷ L1+C2 ÷
L2)+...(Cn ÷ Ln)
Where:
Em is the equivalent exposure
for the mixture.
C is the concentration of a particular
contaminant.
L is the exposure limit for that substance
specified in subpart Z of 29 CFR part 1915.
The value of Em shall not exceed
unity (1).
DISCUSSION
The Secretary’s
Burden of Proof
The Secretary has the burden of
establishing the employer violated the cited standard. To prove a violation of an OSHA standard, the
Secretary must show by a preponderance of the evidence that (1) the cited
standard applies; (2) the employer failed to comply with the terms of the cited
standard; (3) employees had access to the violative condition; and (4) the
cited employer either knew or could have known with the exercise of reasonable
diligence of the violative condition. JPC Group, Inc., 22 BNA OSHC 1859, 1861
(No. 05-1907, 2009).
The Cited Standard Applies
Section 1915.2(a) defines the scope of §
1915:
Except where
otherwise provided, the provisions of this part shall apply to all ship
repairing, shipbuilding and shipbreaking employments and related employments.
Trinity builds barges at its Ashland City facility (Joint Prehearing Statement, p. 3). This activity is “shipbuilding employment” and is covered by part 1915. It would appear the cited standards, §§ 1915.1000(d)(1)(i) and (2)(i), apply to the cited conditions.
Trinity argues, however, there is a more specific standard that applies to the cited conditions.
[Section] 1915.51, titled Ventilation and Protection in Welding, Cutting and Heating, tells employers how to protect their employees from unsafe accumulations of contaminants when welding in a marine environment. It states that Trinity had the choice of protecting its employees from contaminants by either providing mechanical ventilation or providing respirators. Trinity’s choice of providing respirators to its employees was therefore in complete compliance with this directly applicable standard, and an acceptable method of protecting its employees. This directly applicable standard controls over the hierarchy of controls argument espoused by the Secretary.[3]
(Trinity’s brief, p. 3) (emphasis in original)
While there may be merit to Trinity’s argument that § 1915.51 is more specific to the cited conditions than § 1915.1000(d), that argument is an affirmative defense.
Under Commission precedent, preemption by a
more specifically applicable standard is an affirmative defense which the respondent must raise in its answer. 29 C.F.R. §
1910.5(c)(1); see Commission Rules 34(b)(3) and(4), 29 C.F.R.
§ 2200.34(b)(3) and (4); Safeway, Inc. v. OSHRC, 382 F.3d 1189,
1194 (10th Cir. 2004); Vicon Corp., 10 BNA OSHC 1153, 1157, 1981
CCH OSHD ¶ 25,749, p. 32,159 (No. 78-2923,1981) (describing a claim that a
general standard was preempted by a more specific standard as an affirmative defense). Here, despite the Secretary's reference in the citation to a
lack of specificity and similar testimony elicited at the hearing, Spirit
neither raised this issue as a defense in its answer nor sought to amend its
answer to add it. Therefore, we find that the argument was waived. See Gen'l
Motors Corp., Chevrolet Motor Div., 10 BNA OSHC 1293, 1296-97, 1982 CCH
OSHD ¶ 25,872, p.32,361 (No. 76-5344, 1982).
Spirit Aerosystems, Inc., 25 BNA OSHC 1093, 1097, n. 7 (No. 10-1697, 2014).
In its answer,
Trinity asserted one affirmative defense, that of unpreventable employee
misconduct:
Affirmative Defenses
The
violations alleged in the citation and the Complaint were isolated instances of
employee misconduct of which Respondent had no knowledge and which Respondent
could not have reasonably foreseen. Respondent reserves the right to amend its
answer to include additional defenses, should same be necessary.
(Answer, ¶ II)
Trinity
did not subsequently amend its answer to include preemption of the cited
standard by a more specific standard, nor did it raise the defense in the Joint Prehearing Statement or at the
hearing. Accordingly, I find Trinity’s
argument is waived. Sections
1915.1000(d)(1)(i) and (2)(i) apply to the cited conditions.
The Secretary Failed to Prove the Terms
of the Standard Were Violated
Item 2a
The Secretary cited
three instances where the sampling of Trinity’s employees showed they were
overexposed to air contaminants. Instance
(a) alleges overexposure to zinc oxide.
Instances (b) and (c) allege overexposure to particulates not otherwise
regulated (total dust).
Exhibit
C-6 is a copy of the test results for the sampling taken from Employee #1. It shows he was exposed to an eight-hour TWA
concentration of 11.1140 mg/m³ of zinc oxide, which is two times the PEL of 5
mg/m³. Exhibit C-7 is a copy of the test
results for the sampling taken from Employee #2. It shows he was exposed to an eight-hour TWA
concentration of 16.9210 mg/m³ of particulates not otherwise regulated (total
dust), which is 1.128 times the PEL of 15 mg/m³. Exhibit C-8 is a copy of the test results for
the sampling taken from Employee #3. It
shows he was exposed to an eight-hour TWA concentration of 22.2490 mg/m³ of
particulates not otherwise regulated (total dust) which is 1.483 times the PEL
of 15 mg/m³.
Item 2b
The Secretary cited one
instance where the sampling of a Trinity employee showed he was overexposed to
zinc oxide and copper. Exhibit C-6 is a
copy of the test results for the sampling taken from Employee #1. It shows he was exposed to an eight-hour TWA
concentration of 11.1140 mg/m³ of zinc oxide and of 0.057 mg/m³ of copper. When these values are input in the mixture
formula, it resulted in a value greater than 1 (Tr. 57).
Paragraph
D.6 of the Joint Prehearing Statement
provides, “Respondent does not contest the chain-of-custody or procedures used
by OSHA to analyze the atmospheric sampling done during the inspection at
respondent’s facility.” Trinity does not
dispute OSHA’s test results show overexposure to the cited contaminants.[4]
The Secretary’s Burden to Establish Feasible Means
of Compliance
The maritime standards
addressing overexposure to air contaminants do not prescribe a method of
compliance. “[W]here a standard imposes
a duty without specifying the means of compliance, the Secretary has the burden
of establishing the existence of a specific and technologically feasible means
of compliance as an element of his showing that a violation has occurred.” Diebold,
Inc. v. Marshall, 585 F.2d 1327, 1333 (6th Cir. 1978). The Secretary takes the position the
respiratory protection standard at 29 C.F.R. § 1910.134, made applicable to the
maritime industry by 29 C.F.R. § 1915.154, requires an employer to first
implement all feasible engineering and administrative controls before using
respirators to protect employees who are exposed to air contaminants regulated
under § 1915.1000. CSHO Provins
testified the respiratory protection being used by the exposed employees was
“the type of device that would control that type of exposure.” (Tr. 75)
He found no fault with the manner in which the respirators were being
used by Trinity employees (Tr. 75-76).[5] The gravamen of the Secretary’s theory of
the violation is Trinity’s failure to implement feasible engineering and
administrative controls. The evidence
presented by the Secretary fails to meet his burden to establish a violation of
the cited standard under that theory.
The Secretary
called Glenn Lamson as his expert witness on the issue of feasibility of
engineering controls. Lamson is an
industrial hygienist with OSHA’s Health Response Team (Tr. 103-104). Exhibit C-12 is a copy of his expert report.
After visiting the bottoms area of Trinity’s facility, Lamson
noted fans in the roof and at the end of the building provide general
ventilation. There was no local exhaust
ventilation (LEV) in the bottoms area.
Based on his inspection, Lamson recommended three methods of engineering
and administrative controls that could reduce the exposure of Trinity’s
employees to welding fumes (Tr. 117-118, 121-131). They are local exhaust ventilation,
implementation of increased general exhaust ventilation, and rotation of
employees.
Technological
Feasibility
“A control is technologically feasible if it can be adapted to the employer's
operation and is capable of producing a significant reduction in exposure to
the particular toxic substance.” GAF Corp., 9 BNA OSHC 1451, 1455 (No. 77-1811,
1981).
The Secretary bears the burden
of proof in demonstrating the feasibility of administrative and engineering
controls “when the compliance remedy is based upon a very general statutory or
regulatory command that does not describe for the employer any specific methods
for compliance.” Faultless
Div., Bliss & Laughlin Indus., Inc. v. Sec'y of Labor, 674 F.2d 1177, 1189 (7th
Cir.1982); Modern Drop Forge Co. v.
Sec'y of Labor, 683
F.2d 1105, 1113 (7th Cir.1982). As the
Commission itself has noted, however, “[t]he test of whether administrative
and/or engineering controls are technologically feasible is whether the
controls are ‘achievable’ and capable of producing a significant reduction in
exposure to air contaminants.” Sec'y of Labor v. G & C Foundry Co., 17 O.S.H. Cas. (BNA)
2137, 1997 WL 447196, *4 (Rev. Comm'n 1997). Although a significant reduction
is required, it is not necessary to show that the control would achieve full
compliance. Id. “The Secretary need not [
] propose or prove the feasibility of a detailed abatement program. [She] need
only show that some controls are feasible in an employer's plant.” Sec'y of Labor v. Great Falls Tribune Co., 5 O.S.H. Cas. (BNA) 1443,
1977 WL 8017, *3–4 (Rev. Comm'n 1977) (internal citation omitted). There is no
magic percentage of reduction that is required; all that is required is that
the administrative or engineering control be systemic—so that, unlike with
respirators, an individual employee's mistake cannot eviscerate her
protection—and that it produce a significant reduction in silica.
Chao v. Gunite Corp., 442 F.3d 550, 557
(7th Cir. 2006).
While there is no “magic percentage of reduction”
required, it is still the Secretary’s burden to demonstrate a significant
reduction would result. Here, the
Secretary failed to address this element of his burden. Lamson did not quantify any reductions that
could result from his proposed controls.
Q.: You didn’t do any study or take any
measurements or otherwise quantify in any way the reduction in exposure to
employees that the LEV systems like you propose would bring, did you?
Lamson: I did not.
(Tr. 191)
In GAF Corp., the Commission vacated a
citation for overexposure to airborne silver compounds, based on the
Secretary’s failure to present evidence his proposed controls would result in a
significant reduction in overexposure.
The record before us fails to
indicate whether repair of the ventilation system and implementation of the
other measures suggested by the compliance officer would result in a
significant reduction in the excessive levels of airborne silver compounds.
Because the record is devoid of evidence tending to establish the amount of
reduction that could be expected from the controls suggested by the compliance
officer, we conclude that the Secretary has failed to sustain his burden of
proving technological feasibility.
Gaf Corp., 9 BNA OSHC at 1455.
The Secretary has similarly failed to present evidence
establishing the amount of reduction to airborne contaminants that could be
expected in this case. I find the
Secretary has failed to meet his burden of proof on the issue technological
feasibility of either engineering or administrative controls.
Economic Feasibility
The Court of
Appeals for the Sixth Circuit, to which this case may be appealed, has held
that, while there is no “rigid formula” by which economic feasibility is
analyzed, the Secretary must “weigh the costs of compliance against the
benefits expected to be achieved” by proposed engineering and administrative
controls.
[T[he benefits to employees should weigh heavier
on the scale than the costs to employers. Controls will not necessarily be
economically infeasible merely because they are expensive. But neither will controls necessarily be
economically feasible merely because the employer can easily (or otherwise)
afford them. In order to justify the expenditure, there must be a reasonable
assurance that there will be an appreciable and corresponding improvement in
working conditions. The determination of how the cost-benefit balance tips in
any given case must necessarily be made on an ad hoc basis. We do not today
prescribe any rigid formula for conducting such analysis. We only insist that
the Secretary, and the OSHRC on review, weigh the costs of compliance against
the benefits expected to be achieved thereby in order to determine whether the
proposed remedy is economically feasible.
RMI Co. v. Sec'y of
Labor, U. S. Dep't of Labor, 594 F.2d 566, 572–73 (6th Cir. 1979).
Here, the
Secretary failed to conduct even a rudimentary analysis of the economic burden
of the proposed engineering and administrative controls.
Lamson conceded
he did not consider economic feasibility when proposing his engineering and
administrative controls.
Q.: In considering feasibility you did not take into
account how many extra employees Trinity would have to hire in order to implement
a solution, did
you?
Lamson: No.
Q.: You didn't consider the extra time it might take
to build a barge if one of your solutions was implemented, did you?
Lamson: No.
Q.: Again, when you say something is feasible you're
not saying it's economically feasible, are you?
Lamson: That is correct.
(Tr. 164-165)
Q.: You didn't consider the economic impact to Trinity
of such a program when you said it was feasible, did you?
Lamson: No, I'm looking at feasible controls, not --
no, I did not.
Q.: So when you said that the job rotation program
is feasible at Trinity, you do not mean that it was economically feasible, do
you?
Lamson: I don't have the information to answer that.
Q.: All right, so you can't say that it was economically
feasible, correct?
Lamson: No, I'm not an economist.
.
. .
Q.: You cannot say that a job rotation program at
Trinity would be economically feasible, can you?
Lamson: No.
(Tr.
149-150)
I
find the Secretary failed to establish his proposed engineering and
administrative controls are economically feasible.
The
Secretary presented no evidence establishing the respirators used by Trinity
employees were inadequate to protect them from the air contaminants to which
they were exposed. To the contrary, CSHO
Provins testified the respirators were adequate. Nothing in the language of the cited
standards prohibits an employer from using respirators to meet its compliance
obligation.[6] The Secretary has failed to meet his burden
to establish Trinity did not protect its employees from the cited air
contaminants.
Trinity Did Not Have
Knowledge of the Violative Condition
Had the Secretary
successfully established Trinity was in violation of the cited standards, I
would, nevertheless, vacate the citations because he failed to establish
Trinity had knowledge of the violative conditions. In its brief, the Secretary relies solely on
general statements made by CSHO Provins to establish Trinity knew of the
violative conditions to which its employees were exposed.
Basically
these employees are employed by Trinity, they are given their work tasks to do
the welding, Trinity provides -- purchases and provides the materials to
fabricate the barges and oversees the work tasks that are being done.
(Tr.
55)
[Trinity] had done
previous monitoring. They are in and out
of the job site through the course of the work day or work week. They know that the employees are doing these
work tasks. And that this material is
being produced and employees are exposed to them.
(Tr. 57-58)
This
is not a particularly persuasive argument.
Although Trinity was aware of the existence of the cited air
contaminants at its facility, the Secretary presented no evidence Trinity had
actual knowledge its employees were exposed to the cited air contaminants at
levels that exceeded the permissible exposure limits. Nor did the Secretary show Trinity failed to
exercise reasonable diligence such that it should have known of the violative
condition.
In
cases involving employee exposure to air contaminants, the Commission has held:
If an employer knows
that a regulated air contaminant is present in its facility, reasonable
diligence requires that it measure the amount of the contaminant to determine whether
it is present in an excessive amount. See North American Rockwell Corp., [2
BNA OSHC 1710 (Nos. 2692 & 2875, 1975)].
When the Secretary alleges that the contaminant is present in excessive
amounts, but the employer shows that it had made measurements and determined
that the concentration was not excessive, the burden is on the Secretary to
show that the employer’s failure to discover the excessive concentration
resulted from a failure to exercise reasonable diligence.
General Electric Co., 9 BNA OSHC 1722, 1728
(No. 13732, 1981); see also Milliken
& Co., 14 BNA OSHC 2079, 2083 (No. 84-767, 1991).
Trinity
provided evidence of its sampling history and absence of any test results over
the past decade showing overexposure to air contaminants. Michael Stripe is Trinity’s vice-president of
safety (Tr. 298). He testified Trinity
had hired ESIS, “a third party consulting group,” to perform “industrial
hygiene work” for the company (Tr. 299).
That has included, for the past ten years, “probably ten industrial
hygiene surveys throughout” the Ashland City facility (Tr. 300). ESIS conducts sampling for overexposure to
air contaminants, including in the bottoms area at issue (Tr. 301). Stripe receives copies of all the test
results from ESIS. He has never seen a
report showing contaminant exposure above the PEL for a welder at Trinity (Tr.
302). The Secretary presented no evidence to rebut this testimony.
Here,
Trinity hired a third party consultant to monitor air contaminant exposure in
the bottoms area. Trinity provides
welders with respirators and requires the welders to use them (Tr. 243, 258-59,
303).[7] Trinity has a written respiratory protection
program (Tr. 63). Trinity’s actions
demonstrate it inspected the work area, anticipated hazards to which employees
may be exposed, and took measures to prevent the exposure. Trinity exercised reasonable diligence with
regard to the exposure of its welders to air contaminants.
I find the
Secretary failed to establish Trinity had either actual or constructive
knowledge of the violative condition.
Having failed to prove either that Trinity was not in
compliance with the cited standards or had knowledge of the alleged violative conditions,
the Secretary has failed to establish Trinity violated the cited
standards. Items 2a and 2b are vacated.
FINDINGS
OF FACT AND CONCLUSIONS OF LAW
The
foregoing decision constitutes the findings of fact and conclusions of law in
accordance with Fed. R. Civ. P. 52(a).
ORDER
Based on the foregoing decision, it
is hereby ORDERED:
1. The parties’ Stipulation of Partial Settlement and Motion to Withdraw Notice of
Contest with Regard to Settled Items is approved, and
2. Items 2a and 2b
of Citation No. 1, Docket No. 16-0932, are VACATED,
and no penalty is assessed.
SO ORDERED. /s/
Judge Heather A. Joys
1924 Building,
Suite 2R90
Date:
January 16, 2018 100
Alabama Street, S.W.
Atlanta,
Georgia 30303-3104
Phone: (404) 562-1640
Fax: (404) 562-1650
[1] In the attached order, I approve
the parties’ partial settlement agreement.
[2] There is a discrepancy both within
the text of Items 2a and 2b of the Citation (the inspection date is listed as
“10/28/15” but each of the four instances listed in the alleged violation
descriptions (AVDs) starts “On or about October 25, 2015.”) and with the
parties’ Joint Prehearing Statement (“An
inspection was conducted on or about October 29, 2015.” (p. 3)). CSHO Provins answered, “Yes,” to the
question, “Did you conduct a work place inspection of Trinity Marine’s facility
on or about October 25, 2015?”(Tr. 18)
OSHA’s paperwork for the sampling indicates it took place on October 29,
2015 (Exhs. C-1, C-6, C-7, C-8). It is undisputed OSHA’s inspection and
sampling were conducted in late October of 2015.
[3]Trinity argues the relevant
subparagraphs of § 1915.51 are §§1915.51(d)(1) and (f)(1). Section 1915.51(f)(1) provides:
Welding, cutting and heating not involving
conditions or materials described in paragraph (c), (d) or (e) of this section
may normally be done without mechanical ventilation or respiratory protective
equipment, but where, because of unusual physical or atmospheric conditions, an
unsafe accumulation of contaminants exists, suitable mechanical ventilation or
respiratory protective equipment shall be provided.
Sections
1915.51(d)(1) provides:
Welding, cutting or heating in any enclosed
spaces aboard the vessel involving the metals specified below shall be
performed with local exhaust ventilation in accordance with the requirements of
paragraph (b) of this section or employees shall be protected by air line
respirators in accordance with the requirements of § 1915.154:
(i) Metals containing lead, other than as an impurity, or metals
coated with lead-bearing materials.
(ii) Cadmium-bearing or cadmium
coated base metals.
(iii) Metals coated with
mercury-bearing metals.
(iv) Beryllium-containing base or
filler metals. Because of its high toxicity, work involving beryllium shall be
done with both local exhaust ventilation and air line respirators.
[4] Nor can Trinity
contest its employees had access to the cited hazard of overexposure. In their Statement
of Agreed Facts, the parties stipulated, “One or more of respondent’s
employees had access to the conditions cited in Citation 1, Items 2(a) and
2(b).” (Joint Prehearing Statement, ¶
D.5; Tr. 9-10) Despite this stipulation,
Trinity argues in its brief that the Secretary failed to establish employee
access the hazard of overexposure to certain contaminants contending the
Secretary’s “sampling was inadequate because the CSHO did not place the
sampling medium inside the welders’ welding hoods.” Having stipulated to this central fact, Trinity
cannot now, post-hearing, deny it agreed its employees had access to the
violative condition.
This Court has accordingly refused to consider a
party's argument that contradicted a joint “stipulation [entered] at the outset
of th[e] litigation.” Board of Regents of Univ. of Wis. System v.
Southworth, 529 U.S. 217, 226, 120 S.Ct. 1346, 146 L.Ed.2d 193 (2000).
…[F]actual stipulations are “formal concessions ... that have the effect
of withdrawing a fact from issue and dispensing wholly with the need for proof
of the fact. Thus, a judicial admission ... is conclusive in the case.” 2 K.
Broun, McCormick on Evidence § 254,
p. 181 (6th ed.2006) (footnote omitted). See also, e.g., Oscanyan
v. Arms Co., 103 U.S. 261, 263, 26 L.Ed. 539 (1881) (“The power of the
court to act in the disposition of a trial upon facts conceded by counsel is as
plain as its power to act upon the evidence produced.”).
Christian Legal Soc. Chapter of the Univ. of
California, Hastings Coll. of the Law v. Martinez, 561 U.S. 661, 676–78 (2010).
[5] The Secretary argued there was not
“reliable testimony” either way on whether one of the cited welders was wearing
respiratory protection. CSHO Provins
testified his air sampling worksheet indicated the welder was wearing a
respirator and he had testified in deposition all three welders were wearing
respiratory protection. He testified at
the hearing his field notes were silent on the issue. It is the Secretary’s burden to establish
non-compliance. To do so, he would have
to show the welder was not wearing respiratory protection. In failing to present “reliable testimony” on
this issue, the Secretary has not met his burden.
[6] Although other standards addressing
exposure to air contaminants specify exposure levels are without regard to
personal protective equipment (see, e.g.,
29 C.F.R. §§ 1910.1025(d)(1)(i); 1910.1027(a); 1910.28(b); and 1926.62(d)(ii)),
the cited standards do not.
[7] CSHO Provins testified employees he
interviewed told him wearing respirators was not mandatory (Tr. 63-64). I do not credit this testimony. CSHO Provins was no longer working for OSHA
at the time of the hearing. His memory
of the inspection he conducted almost two years before appeared hazy. He initially testified the three employees he
sampled were not wearing respirators at the time of the sampling. After being confronted with which deposition
and the air sampling worksheets he had filled out, he changed his testimony
(Exhs. C-6, C-7, C-8; Tr. 71-75).