SECRETARY OF LABOR,
Complainant,
v.
COLLIER-KEYWORTH COMPANY,
Respondent.
OSHRC DOCKET NO. 80-2848
ORDER
Before: BUCKLEY, Chairman, and AREY, Commissioner.
BY THE COMMISSION:
The parties reached a settlement agreement during appeal proceedings in this case in the United States Court of Appeals for the First Circuit. The court dismissed the appeal in accordance with the joint motion of the parties reciting the existence of the settlement agreement. McLaughlin v. Collier-Keyworth Company, No. 88- 2140 (1st Cir., March 22, 1989). In its mandate, the court stated:
The case is remanded to the Occupational Safety and Health Review Commission with instructions to vacate its decisions and orders in this case in accordance with the settlement agreement.....
In accordance with that mandate, the Commission's order and decision in this case are vacated. Part 1 (a) of the citation for violation of 29 C. F. R. § 1910.95 (a) is affirmed. Parts 1 (b) and 1 (c) of the citation for violation of 29 C. F. R. § 1910.95 (b) are vacated. No penalty is assessed.
FOR THE COMMISSION
RAY H. DARLING, JR.
EXECUTIVE SECRETARY
DATED: April 27, 1989
SECRETARY OF LABOR,
Complainant
v.
COLLIER-KEYWORTH COMPANY
Respondent
OSHRC Docket No. 80-2848
THE REMAND
The Review Commission remanded this case to the Administrative Law Judge "to
afford the Secretary an opportunity to rebut officially-noticed documents with evidence of
the Secretary's intent when he adopted the standard" at
29 C. F. R. § 1910.95 a-b in 1969. [Emphasis added]
The Administrative Law Judge is directed to propose "a supplemental decision affirming, modifying or vacating those citation items relevant to the impulse noise issue in light of any additional evidence that the parties submit."
Part of the Review Commission's decision reads as follows: "...the record in this case contains evidence of events leading up to the adoption of the Walsh-Healey standard .... The parties presented witnesses...who were personally familiar with many of the events leading up to the standard's adoption. This testimony is supplemented by documentary exhibits introduced by the parties and other documents that we officially notice .... The documents we officially notice include only Labor Department publications and scientific papers cited in documents that were introduced into evidence ... Our purpose in taking official notice is not to determine whether impulse noise is harmful or whether the pre-ponderance of scientific thinking in 1969 would have favored the regulation of impulse noise under Table G-16 .... Our purpose is instead to determine the intent of the Secretary in 1969 by examining the body of knowledge on impulse noise that influenced the adoption of the standard. Because our decision rests in part on these officially noticed documents, we shall afford the Secretary an opportunity to rebut them with documents and other evidence of his intent when he adopted the standard." [Emphasis provided]...Review Commission decision, pages 14, 15.
History-of-the-Standard
The Technical Committee on Noise of the American Industrial Hygiene Association [AIHA] suggested a committee of noise experts to recommend guidelines. The Labor Department agreed, and the Inter-Society Committee on Guidelines for Noise Exposure Control came into being. The so-called Inter-Society Committee had two members from each of five technical societies: the AIHA, the ACGIH [American Conference of Governmental Industrial Hygienists], the American Academy of Ophthalmology and Otolaryngology, the American Academy of Occupational Medicine, and the Industrial Medical Association. Herbert H. Jones was Chairman of the ACGIH and one of the ACGIH representatives was Van Atta who, according to Jones, had primary responsibility in the noise area for the Labor Department ....
The inter-Society Committee report [1967] had criteria for only "steady" noise [which would be non-impulsive noise].
Later ACGIH proposed a standard, and in the proposal it twice stated that its proposed limits would "not apply to impulse or impact type of noise."
The Review Commission pointed out that "the criteria proposed by both the
Inter-Society Committee and the ACGIH committee excluded impulse noise, with the exception
of the ACGIH proposal for a peak limit of 140 dB for impulse noise...
On September 20, 1968, the Labor Department published a proposed standard to regulate
workplace noise exposure. 33 Fed. Reg. 12458, 14259-60. This proposed standard bore very
little resemblance to the present standard... and included impulse noise in its exposure
calculations.
And on January 17, 1969, the Labor Department issued a Walsh-Healey noise standard very similar to that which had been proposed and retaining the provision on impulse noise. However, this proposal standard was stayed by the Secretary of Labor ... 34 Fed. Reg. 2207.
On May 20, 1969, the Labor department issued a new standard that (in the words of the Review Commission) "is identical to the one at issue in this case. Major differences between the earlier standard and the later standard include provisions relevant to the impulse noise issue. The earlier standard explicitly stated that ... impulse noise was to be included in weekly exposure calculations. However, the final standard contained no similar provision and included a provision with no counterpart in the earlier standard--a recommended limit of 140 dB for impulse noise."
The Review Commission concluded that: "The final standard strongly resembled that adopted by the ACGI: on May 12, 1969 ..."..... Review Commission, 15-21.
To summarize the Review Commission's apparent analysis: On September 20, 1968, the Labor Department's proposed standard included impulse noise in its exposure calculations. And on January 17, 1969, the Labor Department proposed a standard that retained the provision on impulse noise, but the Secretary of Labor stayed it.
Then on May 20, 1969, the Labor Department issued a standard that had no provision including impulse noise in exposure calculations but had a recommended limit of 140 dB for impulse noise.
The Review Commission also said: "Jones was still Chairman of the ACGIH Committee; he stated that Dr. Van Atta of the Labor Department had been aware of the wordings of the Committee and of its proposed standard..." ... Review Commission decision 21.
As the Review Commission pointed out, the standard must be given the same meaning it had under the Walsh-Healey Act ... Review Commission decision 14.
The Labor Department's Bulletin 334 of December 4, 1970, revised on June 8, 1971, indicates that the Secretary was aware of the scientific reasons why impulse noise is excluded from the standard... Review Commission decision 27. It is also consistent with the Review Commission's finding that the evidence is overwhelming that OSHA interpreted the standard to exclude impulse noise from Table G -16... Review Commission decision 32.
The Remand Transcript
Because the Remand was heard at various dates, the four volumes of the Remand Transcript are herein designated by the roman numerals I, II, III, and IV preceding the page number.
Scope of the Remand
In addition to the usual rules of evidence, the testimony and evidentiary exhibits were further restricted by the parameters of the Review Commission's Remand order: "..... evidence of the Secretary's intent when he adopted the standard in 1969."
Excluded Evidence
There were several rejected proffers of evidence, However, even if any or all of such evidence had been admitted, it was not of sufficient weight or credibility to affect any finding or the decision.
The Issue
The question on Remand is not whether employees are better protected if impulse/impact noise is included in determining if the limitations imposed by the table G-16 were exceeded; it is rather to determine whether the Secretary of Labor intended to have impulse/impact noise included in table G-16, for whatever reasons
Findings and Conclusions
I have considered the briefs and the Respondent's 161 proposed findings of fact and conclusions of law. To the extent shown herein these are adopted; otherwise, they are rejected as not being supported by the evidence or law or as being immaterial or irrelevant or beyond the scope of the Order of Remand.
Testimony at Remand Hearing
Four witnesses testified at the Remand Hearing: Davis, Kamperman, Ward and Hildyard. Part of their testimony is summarized below.
[1] Irving Davis
Davis, a retired industrial hygiene engineer, was involved in sampling employee exposure to noise in Michigan, and dealt predominantly with the Michigan noise standard (I, p.16,17). He was a member of the American conference of Governmental Industrial Hygienists ("ACGIH") since the early 1950's and was appointed to the Physical Agents Committee from 1967 to the present. Davis was also a member of the American Industrial Hygiene Association in 1969 and 1971. (I, p.19-20)
Davis' testimony revealed that all work places had a mix of steady-state and impact/impulse noise (I. p.18, 36) and that the threshold limit value included all noise; he stated that impulse/impact noise should not and could not be practically edited from a noise survey (I, p.36). Further, that the intent of the noise standard proposed by the ACGIH committee in 1968 (Review Commission Decision, Appendix, P.57) was that it did not apply to "peak" measurements of impact or impulse noise. It did not mean that impact or impulse noises should be edited or excluded from the total noise measurement (I, p.27-28). Although Davis agreed that the qualifying term "peak" did not appear in his committee's definition of impulse/impact and continuous noise "we understood that to be 'peak'." (I, pp. 75-76). However, he testified only to his "personal understanding" of this; Davis could refer to no written evidence of this interpretation (I, pp. 27-28). He was unable to provide any state or federal OSHA noise standard interpretation, or any documents relating to impulse noise measurements (I, pp. 78-79).
Similarly, Davis was aware of the statement in Bulletin 334 of the Department of Labor (R66 of Review Commission Decision) which explained, in part, that "[i]n contrast with 115 dBA upper limit for steady noise, the higher intensity for impact noise is permissible because noise impulse resulting from impact... is passed before the ear has time to react fully." He understood that this was based on available scientific and medical evidence, but that his personal understanding of this was that it was intended to apply only to peak sound pressure (I, p. 147-148). In contrast, at his deposition, Davis did not limit his answer to "peak", stating that he understood that all impulse/impact sound did not reach the inner ear (I, p.148)
In R11, a copy of The Physical Agents Committee's document referring to the values
expressed in the ACGIH TLU, it states that "[t]hese values ... [do] not apply to
impact or impulse type of noises." Davis understood this to mean "peak"
measurements of impact or impulse noise (I, p.183).
Davis was not involved in any Department of Labor meetings concerning the development of
federal OSHA standards (I, p.117-118). He never discussed the noise standard or impulse
noise with Van Atta (I, p.119). He did not participate or have personal knowledge of what
went in to the promulgation of the Occupational Noise Standards under Walsh-Healey (I,
p.120) nor was he involved in the Inter-Society Committee (I, p.104).
Davis was unaware of any Department of Labor documents, from 1968 to 1970 that discussed the interpretation of the noise standard and whether impact/impulse noise was or was not required to be included for enforcement purposes, nor did he discuss the subject with OSHA personnel (I, p.137). However, his office received "CPL's" (documents intended to provide interpretations of Federal OSHA standards) throughout the 1970's (I, p.173-174).
[[2]] George Kamperman
Kamperman, a consulting engineer in noise control and sound level meters, was a member of several American National Standards Institute (ANSI) committees, one of which studied the performance characteristics and capabilities of sound level meters (I, p.194; II, p.223).
The focal point of Kamperman's testimony involved a June 11 and 12, 1969 symposium on industrial noise, which was held to discuss the implications of the Walsh-Healey Act which had been promulgated in May, 1969. (II, p.244).
Dr. Floyd Van Atta, from the Department of Labor, was invited to speak, as he was considered the "architect" of the noise regulation standard in the Walsh- Healey Act (II, p.245-246). He discussed the background of the new noise standard and how it was to be enforced by the Department of Labor (II, p.247). Panel discussions were held and Kamperman engaged in informal discussions with Van Atta at the time (II, p. 247, 263). Kamperman's basis for testifying to Van Atta's position with respect to impulse/impact noise was founded on four such informal meetings, two taking place at dinners on the evenings before each day's symposium meeting (II, p.248), and two other seminar meetings, the date and location of which Kamperman could not recall (II, p.324-325).
Throughout his testimony, Kamperman stated what he remembered to be Van Atta's position (thus, the Department of Labor's) with respect to the Walsh-Healey noise standard, which he gleaned from informal meetings and Van Atta's symposium presentation. He recalled that Van Atta believed that all noise in an industrial environment, including impact/impulse noise, was to be in the Table G-16 computation, and that there was an additional requirement that impact/impulse noise not exceed 140 dB peak sound pressure (II. p.249,253,262,268,275,278).
However, Kamperman had never seen a document or official agency interpretation, including OSHA CPL's for noise standards or noise measurement, nor any other written interpretation for the Department of Labor, or OSHA, instructing employers to include impulse noises in Table G-16 when making noise measurements (II, p.305,354,360,361). The handouts at the symposium did not cover impact/impulse noise or its computation under Table G-16 (II, p.295-296). Kamperman could not recall Van Atta's opening or closing remarks of his speech and could not quote anything that Van Atta said during the two-day symposium (II, p.318). Kamperman stated that he was not a "careful note taker"; he took no notes of Van Atta's speech and knew no one who did (II, p.290, 321, 335). Kamperman could not recall any specific statements by Van Atta about the source of the Walsh-Healey noise standard (II, p.328), nor was he aware of any of Dr. Van Atta's writings (II, p.346).
Kamperman stated at his deposition that he was "not capable of recalling things " (II, p. 335). He had never worked with Van Atta on a day-to-day basis (II, p.360).
[3] W. Dixon Ward
Ward, a professor at the University of Minnesota, teaches, consults and does research in the field of noise and its effects on humans and animals (II, p.365). In the 1950's and 60's, his research dealt with the effects of impulse noise (II, p.368). Ward was chairman of the working group of the Committee on Hearing Environmental Acoustics which put out a proposed damage risk criteria for impulse noise in 1968.
Ward's testimony indicated that, as of 1969, there is no sound, scientific basis for excluding the impulse noise component from the total worker noise exposure calculation used to protect hearing; both steady-state and impact noise are potentially hazardous in an industrial environment (II, p. 380, 381, 384, 396),. However, he also noted that before 1971, there were scientific studies that indicated impact/impulse noise situations should be treated separately from continuous or steady- state noise (III, p.62). His understanding of the original OSHA noise standard was that its permissible exposure level for non-impulse noise at 90 for an eight hour duration is less than or equal to 140 dB peak for impulse noise regardless of its duration (II, p.448-449). Ward was not aware of any documents that interpreted how impact noise was to be treated under the OSHA noise standard (III, p.158-160)
Ward had no personal participation or knowledge of the promulgation processes, events or discussions that resulted in both the Walsh-Healey or OSHA noise standards (II, p.370, 448; III, p. 31-33). He was not familiar with Dr. Van Atta's writings until this hearing (II, p.449). Ward had never had discussions with Van Atta concerning impact/impulse noise or its measurement under Table G-16 (III, p.46). He was unfamiliar with the identities of any of the draftsmen for the Walsh-Healey or OSHA noise standards (III, p.33).
[4] Victor Hildyard
Hildyard, a physician and surgeon and specialist in otology, had encountered the effects of impact/impulse noise in clinical practice. He was appointed by Undersecretary of Labor Guenther to be chairman of the OSHA Standards Advisory committee in 1972 (III, p.196). The fifteen-person committee, which met in 1973, in meetings open to the public, reviewed and evaluated noise standards relating to permissible levels of exposure, reviewed the history of the criteria documents that led up to the original noise standard of OSHA and Walsh-Healey, collected information on new research and development performed since the original standard and made recommendations to the Secretary of Labor for a revised noise standard (III, p.196, 218, 219). Dr. Van Atta, as a representative of the Department of Labor, was an advisor to the committee (III, p. 196), and as such, outlined the course and objectives of the group, and assisted in tracing the history of the standards (III, p.234-235, 219). Van Atta would prepare and edit the Committee's recommendations into a final draft to be sent to the Secretary of Labor (III, p.229). Van Atta was present, as advisor, at every committee meeting (III, p.230).
Hildyard had numerous private discussions with Dr. Van Atta in 1973 concerning the
inclusion or exclusion of impulse noise from Table G-16 (IV, p.232, 280). At the time, Dr.
Van Atta expressed the Department of Labor's position with respect to permissible noise
level exposure for continuous noise, worker protection, and impulse noise (IV, p.232-233).
It was the Department of Labor's position, as expressed by Van Atta, that impulse noise
could not be included in Table G-16, as impact/impulse noise and continuous noise were to
be measured separately and had distinct damage risk criteria; impulse noise could not be
integrated into the Table, or the threshold limit values, or the permissible noise values
for continuous noise (IV, p.235-236, 280, 281, 283). In addition, the departmental
position, according to Van Atta, and based on ACGIH conclusions and studies, was that the
human ear treats these two types of noises differently (IV, p. 235, 237-239). Dr. Van Atta
stated that the Department of Labor's position was that if a worker stayed within the
permissible limits of 140 dB peak for impulse noise, for a working day over a working
lifetime, his hearing would not be in any danger (IV, p.239- 240). Hildyard testified that
Van Atta stated that, in 1969, the Department of Labor intended to treat impulse noise
differently from continuous noise, as he used the Walsh- Healey standard as a starting
point for the Committee to continue its work
(IV, p. 237, 255, 282). Van Atta's position in 1973 was the same as it was in 1969 (IV, p.
282).
The Secretary of Labor's representative
All the facts, and the inferences to be drawn from them, indicated quite clearly that the Secretary of Labor was represented by Van Atta, a Labor Department employee who participated in proceedings pertaining to the noise standard in question. In fact, the Complainant stipulated that Van Atta was (in 1973):".... an employee of the Department of Labor and he was at this committee meeting in his official capacity..." ... Tr. IV 251. And both sides, at one time or another, took the position that Van Atta represented the Secretary of Labor in matters pertaining to the noise standard.
Discussion
An analysis of the testimony of each of the four witnesses who testified on remand [Davis, Kamperman, Ward, and Hildyard] makes it clear that the decision on remand must be largely based on a choice of relying on either the memory of Kamperman or that of Hildyard. That is because the best evidence of the intent of the Secretary of Labor--the stated aim of the hearing on remand--would be best disclosed by the conduct and statements of the Secretary's representative (van Atta). Of the four, only Kamperman and Hildyard gave specific instances of such conduct and statements by van Atta. Should one be relied on more than the other?
I find that both Kamperman and Hildyard were extremely well qualified in their fields of expertise; and I find that both were equally candid and honest in their testimony.
I find that both have tried equally hard to recall events that happened many years before the hearing. However, I find that the memory of Hildyard was more likely to recall specific details of conduct and statements by van Atta because, as Chairman of the Committee to which van Atta was advisor, Hildyard would in all probability have had more communications with van Atta, and more reason to pay attention to van Atta's statements and conduct, than Kamperman or other committee members. For primarily that circumstance, I find that the memory of Hildyard is to be relied on more than anyone else's when [as here] it is a question of great concern to the committee he chaired.
I find that, when the standard in question was adopted in 1969, it was the Secretary of Labor's intent that impact/impulse noise should not be included in table G-16.
Accordingly, as the Review Commission said in its decision of April 6, 1987, which is followed and affirmed by the undersigned: "..... we vacate citations item 1a (B) and (D), and ib (b) and (D) ...... We vacate items 1a (A) and (C) ... And we vacate items 1b (A) and (C)."
SO ORDERED.
Recommendation
Regardless of the ultimate outcome of this case, no tribunal concerned with justice and due process of law should tolerate a potential situation where neither the Complainant nor the Respondent can be reasonably certain of exactly what a standard mandates. The meaning of its words should not have to be determined by implication or interpretation or speculation or guesswork.
And certainly a standard should not be so worded that it possibly could call for the use of tools or implements or testing methods that necessarily result in erroneous measurements or conclusions. Unfortunately, the standard here is subject to such flaws.
The Labor Department is strongly urged to take the necessary steps to have the standard be amended or re-worded so that its meaning is crystal clear to all who may be concerned in its enforcement.
FOSTER FURCOLO
Judge, OSHRC
Dated: August 24, 1988
Boston, Massachusetts
SECRETARY OF LABOR,
Complainant,
v.
COLLIER-KEYWORTH COMPANY,
Respondent.
OSHRC Docket No. 80- 2848
ORDER OF REMAND
On April 6, 1987, the Commission issued a decision holding that Table G-16 of the occupational noise standard at 29 C. F. R. § 1910.95 (a)-(b) did not cover impulse noise. The Commission based its holding on the language of the standard, its legislative history and the Secretary's interpretation of the standard shortly after its adoption. In weighing the legislative history of the standard and the Secretary's interpretation of the standard shortly after its adoption, we referred to documents that we officially noticed under section 7 (d) of the Administrative Procedure Act, 5 U. S. C. § 556 (e). We also stated that we would afford the Secretary the opportunity to rebut the officially-noticed documents with documents and other evidence of his intent when he adopted the standard in 1969. The Commission therefore ordered that certain citation items be vacated unless the Secretary requested an opportunity within 15 days to rebut officially-noticed documents.
The Secretary has filed a motion for an extension of time to gather, review and possibly submit documents relevant to the intent of the standard's drafters with respect to the coverage of impulse noise. The Secretary asks for extension of three weeks, through May 11, 1987. Ordinarily, we would simply grant this motion, for it is supported by good cause. In this case, however, the Secretary's motion would, if granted, cause the period of time to extend beyond the term of one of the Commission's two current members. The Commission might for some time therefore be unable to directly act on further motions in the case and might be unable to remand the matter to the administrative law judge to receive further documents and supporting testimony. Inasmuch as this issue is an important one and should be expeditiously resolved, we will grant the motion and remand this case to the administrative law judge now with instructions to afford the Secretary an opportunity to rebut officially-noticed documents with evidence of the Secretary's intent when he adopted the standard in 1969. The judge shall expeditiously prepare supplemental decision affirming, modifying or vacating those citation items relevant to the impulse noise issue in light of any additional evidence that the parties submit. If the Secretary does not desire that the record be re-opened, the judge shall issue a decision vacating the citation items in accordance with our decision of April 6, 1987.
Accordingly, this case is remanded to the administrative law judge for further proceedings.
FOR THE COMMISSION
Ray H. Darling, Jr.
Executive Secretary
DATED: April 22, 1987
SECRETARY OF LABOR,
Complainant,
v.
COLLIER-KEYWORTH COMPANY,
Respondent.
OSHRC Docket No. 80-2848
DECISION
Before: BUCKLEY, Chairman; WALL, Commissioner.
BY THE COMMISSION:
This case is before the Occupational Safety and Health Review Commission under 29 U. S. C. § 661 (j), section 12 (j) of the Occupational Safety and Health Act of 1970, 29 U. S. C. §§ 651- 678 ("the Act" or "the OSH Act"). The Commission is an adjudicatory agency, independent of the Department of Labor and the Occupational Safety and Health Administration ("OSHA") It was established to resolve disputes arising out of enforcement actions brought by the Secretary of Labor under the Act and has no regulatory functions. See section 10 (c) of the Act, 29 U. S. C. § 659 (c).
I Introduction
Collier-Keyworth Company manufacturers swivel and tilt mechanisms for office chairs in a plant in Gardner, Massachusetts. In April 1980, OSHA industrial hygienists inspected Collier- Keyworth's plant to determine whether the company was in compliance with the occupational noise standard at 29 C. F. R. § 1910.95 (a)-(b). From measurements made during the inspection, OSHA concluded that employees who operated power presses and lathes at the plant were exposed to noise in excess of the limits established by the standard. It therefore cited Collier-Keyworth for various violations of section 1910.95. At the time of the alleged violations, the standard provided:[[1]]
§ 1910.95 Occupational noise exposure.
(a) Protection against the effects of noise exposure shall be provided when the sound levels exceed those shown in Table G-16 when measured on the A scale of a standard sound level meter at slow response.
(b) (1) When employees are subjected to sound exceeding those listed in Table G-16, feasible administrative or engineering controls shall be utilized. If such controls fail to reduce sound levels within the levels of Table G-16, personal protective equipment shall be provided and used to reduce sound levels within the levels of the table.
(2) If the variations in noise level involve maxima at intervals of 1 second or less, it is to be considered continuous.
(3) In all cases where the sound levels exceed the values shown herein, a continuing, effective hearing conservation program shall be administered.
Table G-16--Permissible Noise Exposures [[1]]
Sound level dBA
Duration per day, hours slow response
8..........................................................................................................................90
6..........................................................................................................................92
4..........................................................................................................................95
3..........................................................................................................................97
2........................................................................................................................100
1
1/2..................................................................................................................102
1........................................................................................................................105
1/2.....................................................................................................................110
1/4 or
less.........................................................................................................115
[[1]] When the daily noise exposure is composed of two or more periods of noise exposure
of different levels, their combined effect should be considered, rather than the
individual effect of each. If the sum of the following fractions: C1/T1 + C2/T2)
[+.........] Cn/Tn exceeds unity, then, the mixed exposure should be considered to exceed
the limit value. Cn indicates the total time of exposure at a specified noise level, and
Tn indicates the total time of exposure permitted at that level.
Exposure to impulsive or impact noise should not exceed 140 dB peak sound pressure level.
The principal dispute in this case is whether Table G-16 regulates a kind of noise called "impulse noise." The dispute arises in this case because, in determining whether Collier-Keyworth's employees were exposed to more noise than Table G-16 permits, OSHA employed measuring devices-sound level meters and personal noise dosimeters--that registered impulse noises in Collier- Keyworth's plant. Collier-Keyworth argues that Table G-16 was not intended to regulate impulse noise and therefore that OSHA's measurements were unreliable.
A. Measuring Noise Exposure Under Table G-16
Before we set out and discuss these arguments, we shall discuss generally the two methods of proving that an employer has violated the limits for noise exposure in Table G-16 of section 1910.95 (a)-(b). First, the Secretary may show that an employee is subjected to a sound level equal to or greater than a level listed in Table G-16 for a longer period of time than the table permits. For example, the Secretary could meet his burden of proof by showing that an employee is exposed to 92 dBA or higher for more than six hours, or to 105 dBA higher for more than one hour. If this method is used, however, sound levels that last for less than their permissible periods would have to be disregarded. Yet, sound levels in industrial plants often fluctuate and continue for less than their permissible periods; some last for only a few minutes or seconds. This method therefore can result in a substantial underestimate of an employee's total noise exposure.[[2]]
The second way in which the Secretary can show overexposure overcomes this difficulty but introduces others. The second method uses the cumulation formula in the footnote to Table G-16. This formula explains how one may calculate an employee's noise dosage when sound levels vary throughout the workday. Under the cumulation formula, a fraction, Cn/Tn (Cn being the time the employee is exposed to that level and Tn being the exposure time permitted at that level), is calculated for each different noise level to which an employee is exposed during the workday. At the end of the day, all the fractions thus calculated are added together. If the total is more than one ("unity"), the employee has been exposed to noise exceeding permitted limits.
The cumulation formula yields a more accurave determination of an employee's total noise exposure, for it counts as part of the employee's noise exposure sound levels that continued for less than the permissible period. This permits each variation in noise level to be given its proper weight and to be cumulated. However, the cumulation formula is considerably more difficult to apply. An OSHA compliance officer must hold the microphone of a sound-level meter in an employee's hearing zone; read each different sound level registered on the meter; with a watch, determine the duration of that level; and record on a notepad each sound level and its duration. Where the noise level is constantly varying, however, it is extremely difficult to manually make the many measurements and calculations necessary to apply the formula. And, because the task is so difficult to perform accurately, compliance officers cannot survey the exposure of more than a few employees in a day.
To overcome these problems, the personal noise dosimeter was developed. The dosimeter is an electronic instrument that contains the circuitry of a standard sound level meter along with other circuitry. A dosimeter is small enough to be worn by an employee throughout the workday as he goes about his duties. The dosimeter microphone, which is part of the dosimeter's sound level meter, is placed in the employee's hearing zone, where it continually detects the noise to which the employee is subject. The sound level meter circuitry within the dosimeter measures the varying sound levels and sends that information to the other dosimeter circuitry, which automatically calculates and sums the fraction as required by the cumulation formula.[[3]] At the end of the workday, the dosimeter gives a reading in terms of the percentage of the permitted daily dosage a dosimeter reading of 100 percent means that the sum of the fractions is one. A dosimeter reading exceeding 100 percent thus means that the permitted daily noise dosage has been exceeded. See New England Container Co., 84 OSAHRC 55/A2, 12 BNA OSHC 1368, 1371 n. 7, 1984-85 CCH OSHD (P) 27,148, pp. 35,045-46 n. 7 (No. 78-1539, 1984).
The Secretary measured the noise exposure of Collier-Keyworth's employees using dosimeters. Because the dosimeters indicated that Collier-Keyworth's power press and lathe operators were exposed to more than 100 percent of the permitted daily dosage. The Secretary alleges that the employees were exposed to noise exceeding the limits permitted by the standard. Collier-Keyworth contends that the dosimeter readings cannot be relied upon to find overexposure. The company raises a number of potential inaccuracies with dosimeters, but its principal argument is that the dosimeter readings obtained by the Secretary were unreliable because some of the noise they measured was impulse noise, a type of noise the company argues is not intended to be included in dosage calculations under Table G-16.
B. Impulse Noise
Impulse noise is noise of brief duration produced by a short-lived physical phenomenon, such as a gunshot, a clap of thunder, or a power press stroke. When such noise arises from the impact of two objects, it is called impact noise. The distinction between impact noise and other impulse noise is not important to the issues before us. A provision of the standard, however, requires that we distinguish between impulse noises based on the time between their peaks or maxima. Subsection 1910.95 (b) (2) states that "[i]f the variations in noise level involve maxima at intervals of 1 second or less, it is to be considered continuous". This provision reflects that much industrial noise consists of level of repetitive impulses and that the impulses are often spaced so closely together as to sound continuous. One witness gave the example of a gearbox, in which noise originates as the impact of gear teeth on gear teeth but the impacts occur so frequently that the ear does not hear the individual impacts. Subsection (b) (2) provides a criterion for classifying closely-spaced impulse noise as continuous noise. Concomitantly, expert witnesses for both parties testified that noise is considered to be "impulse noise" if it involves maxima that are less than one second in duration and more than one second apart.
Collier-Keyworth's arguments focus both on the words of the standard and its background. Collier-Keyworth points to a provision that is now printed as the second paragraph of the footnote to Table G-16. That provision states that "[e]xposure to impulsive or impact noise should not exceed 140 dB peak sound pressure level." Collier-Keyworth argues that this provision demonstrates that the standard treats impulse noise differently from other noise. It also points to subsection (b) (2) of the standard. Because the one second interval mentioned in that subsection corresponds to the interval that is universally recognized as the dividing line between impulse noise and continuous noise. The company contends that this represents the standard's intent to draw a line between impulse noise and continuous noise, with the latter regulated by Table G-16 calculation and the former excluded. It also relies on various documents and testimony to support its argument that, when the noise standard was adopted, the Secretary did not intend to regulate impulse noise under Table G-16.
Administrative Law Judge Foster Furcolo agreed with Collier-Keyworth's argument that
Table G-16 was not intended to cover impulse noise. On that basis, the judge vacated the
citations in their entirety. We agree with the judge's conclusion that impulse noise must
be excluded when determining whether Table G-16 limits have been exceeded. We further find
that the employees covered by items 1a(B) and 1b(B) and (D), of the citation were exposed
to considerable amounts of impulse noise, and as to those employees the Secretary
did not prove overexposure to continuous noise. Employees covered by citation items 1a (A)
and (C), and 1b (A) and (C), however, were exposed to noise defined as continuous by
subsection (b) (2) of the standard, i.e., to noise with impulses occurring more frequently
than once per second. Although we find that the Secretary proved that those employees were
exposed to noise exceeding permitted limits, we also find that the Secretary did not show
that Collier-Keyworth failed to take the steps required by the standard to protect the
employees. We therefore affirm the judge's disposition vacating all citation items.
II. Does Table G-16 Cover Impulse Noise?
The record establishes, as we shall discuss more fully later, that at least some of the
noise measured during OSHA's inspection of Collier-Keyworth's plant was impulse noise,
that is, noise with sharp energy peaks lasting less than one second and spaced more than
one second apart. If Table G-16 does not regulate impulse noise-or, stated differently, if
impulse noise must be excluded from the calculation of dosage when one uses the cumulation
formula in Table G-16--then dosimeter readings that include impulse noises produce
readings that are too high. Therefore, in determining whether the readings obtained by
OSHA show that Collier-Keyworth's employees were exposed to excessive noise, we must first
address Collier-Keyworth's argument that section 1910.95 (a)-(b) does not intend for
impulse noise to be included in dosage calculations employing Table G-16 limits. [[4]]
A. The Scope of Our Inquiry
The Secretary contends that Collier-Keyworth's argument should be rejected because the
record compiled in this litigation "contains substantial expert testimony that
impulsive ........ noise is no less damaging to hearing than continuous noise." The
Secretary cites the testimony of several witnesses, including that of a physician
specializing in otolaryngology, and argues that the degree of permanent hearing loss is
directly proportional to the amount of acoustic energy transferred to the ear.[[5]] The
Secretary reasons that because the energy associated with prolonged exposure to impulse
noise can cause irreversible hearing loss, it should be regulated by Table G-16.
We do not dispute that there is now reason to believe that impulse noise can cause hearing
loss. But in the absence of an OSHA standard, we do not have the authority to regulate
exposure to impulse noise. New medical and scientific. evidence is not relevant if, as
Collier-Keyworth claims, the Secretary did not intend Table G-16 to cover impulse noise
when he adopted it. As an adjudicative body, the Commission must take the standard as it
finds it and apply the standard in accordance with the Secretary's intent at the time of
promulgation. See Oscar Mayer & Co. v. Evan, 441 U. S. 750, 758 (1979) (intent of
Congress that enacted statute is controlling). The Commission has no authority to
"update" any standard through interpretation according to the latest scientific
findings. Such legislative authority resides in the Secretary, who, in rulemaking, may
consider whether new findings about physical agents make regulation necessary and what new
duties should therefore be imposed on employers. For the Commission to interpret a
standard to produce what it believes will be greater protection for employees than the
Secretary originally intended both usurps the Secretary's rulemaking authority and
detracts from the statutory right of those affected by a rule to participate in the
rulemaking process.
B. The Language of Section 1910.95 (a)-(b)
The Secretary argues that the plain language of the standard indicates that he intended to
regulate impulse noise under Table G-16. He notes that section 1910.95 (a) requires
protection whenever "sound levels" exceed Table G-16 values, and argues that the
all-inclusive phrase "sound levels" draws no distinction between impulse noise
and non-impulse noise.
Standards must, however, be read as a coherent whole, and Collier-Keyworth points to two
provisions it contends indicate an intent to exclude impulse noise from Table G-16.
Collie-Keyworth points to the statement, now printed as the second paragraph of the
footnote to Table G-16, stating that exposure to peak sound pressure levels of impulse
noise should be limited to 140 dB. It argues that this special provision for impulse noise
shows an intent to treat impulse noise differently from other noise. The Secretary, on the
other hand, contends that this provision demonstrates that where the standard intended to
distinguish impulse noise from other noise, it did so explicitly.
We think that there is force in Collier-Keyworth's argument. Although Table G-16 sets a
ceiling of 115 dBA on sound pressure levels regardless of the duration of exposure,
Wheeling-Pittsburgh Steel Corp., 83 OSAHRC 16/A2, 11 BNA OSHC 1292, 1294, 1983-84 CCH OSHD
(P) 26,482, p. 33,673 (No. 15647, 1983), the special provision for impulse noise warns
against impulse noise that exceeds 140 dB. This provision would be superfluous if, as the
Secretary argues, the all-inclusive phrase "sound levels" in section 1910.95 (a)
means that all sound, both impulse and non-impulse, must stay within the limits in Table
G-16. Thus, the impulse noise provision suggests that the "sound levels"
regulated by Table G-16 do not include all sound levels and that impulse noise must be
excluded from calculations under Table G-16.[[6]]
It might seem somewhat odd that an answer to this important question might be suggested by
a brief second paragraph of a footnote to a table. However, the drafters of the standard
did not intend the impulse noise provision to be relegated to such an obscure position.
The provision was originally placed in the next of the standard but later became located
in the footnote as the result of a printer's error.[[7]] We therefore ascribe no
importance to the placement of the impulse noise provision.
The second provision on which Collier-Keyworth relies is subsection (b)(2), which defines
noise as continuous if the peaks are closer than one second apart. Collier-Keyworth
contends that the Secretary's classification of closely-spaced impulses as continuous
noise must be viewed as evidence of an intent to distinguish impulse noise from continuous
noise and to exclude impulse noise from the criteria established for continuous noise. The
Secretary's brief does not address subsection (b)(2) or suggest how it could be reconciled
with his position that impulse noise is subject to the limits of Table G-16.
We agree with Collier-Keyworth that subsection (b)(2) appears to represent an attempt to
distinguish impulse noise from continuous noise. Both parties agree that continuous noise,
i.e., noise of constant intensity, is included in Table G-16 calculations. By defining
noise with peaks closer than one second apart as continuous, subsection (b)(2) obviously
means that such noise is to be included in dosage calculations. A provision that says
something is included, however, implies that something else is excluded, for there would
otherwise be no reason for the provision. As the one-second criterion in subsection (b)(2)
represents the distinction between impulse noise and non-impulse noise, the section
suggests that the drafters of the standard intended to exclude impulse noise from Table
G-16.
On balance, both the 140 dB peak limit for impulse noise and subsection (b)(2) suggest
that impulse noise is excluded from dosage calculations under Table G-16. Nevertheless,
the standard is not entirely clear on its face. It does not expressly exclude impulse
noise from Table G- 16. As the Secretary points out, the standard uses the broad term
"sound levels." In light of the ambiguity, we look to evidence extrinsic to the
standard to determine whether the drafters intended to exclude impulse noise from such
calculations.
C. Legislative History of the Standard
Section 1910.95 is derived from 41 C.F.R. § 50-204.10, a standard that was originally
promulgated in 1969 by the Labor Department's Bureau of Labor Standards to regulate work
by government contractors under the Walsh-Healey Government Contracts Act, 41 U.S.C. §
35-45. Section 1910.99 (listing sources of standards); see generally American Can Co., 82
OSAHRC 5/A2, 10 BNA OSHC 1305, 1306-1308, 1982 CCH OSHD (P) 25,899, pp. 32,409-11 (No. 76-
5162, 1982)(setting out course of promulgation of standard). Because 41 C.F.R. §
50.204.10 qualified an "established federal standard" under section 3(10) of the
Occupational Safety and Health Act of 1970 ("the OSH Act"), the Secretary of
Labor was authorized to adopt it as an OSHA standard without further rulemaking
proceedings. Section 6(a) of the OSH Act, 29 U.S.C. § 655(a). The Secretary did so on May
29, 1971, adopting 41 C.F.R. § 50-204.10 verbatim as an OSHA standard and codifying it at
29 C.F.R.§ 1910.95. 36 Fed. Reg. 10466, 10513. Because the Secretary did not, and--with
exceptions not pertinent here--could not substantively amend the standard when he
summarily adopted it as an OSHA standard, we must give the standard the same meaning it
had under the Walsh-Healey Act. See American Can, 10 BNA OSHC at 1310-11, 1982 CCH OSHD at
pp. 32,413-14; Sherwin-Williams Co., 84 OSAHRC 28/A2, 11 BNA OSHC 2105, 2109-10, 1984-85
CCH OSHD (P) 26,986, pp. 34,701-02 (No. 14131, 1984).
The promulgation of 41 C.F.R.§ 50-204.10 represented the culmination of a long effort by
the Labor Department and other organizations to develop exposure limits for noise that
would protect workers against noise-induced hearing loss. Although the preamble that
accompanied the standard when it was adopted under the Walsh-Healey Act sheds no light on
the impulse noise question, the record in this case contains evidence of events leading up
to the adoption of the Walsh- Healey standard, as well as evidence of the Secretary's
interpretation of the standard shortly after its promulgation. The parties presented
witnesses, James H. Botsford and Herbert H. Jones, who were personally familiar with many
of the events leading up to the standard's adoption. Their testimony is supplemented by
documentary exhibits introduced by the parties and other documents that we officially
notice under section 7(d) of the Administrative Procedure Act, 5 U.S.C. § 556(e).[[8]]
Our examination of the record and the material that we officially notice, together with
the words of the standard, lead us to conclude that the Secretary did not intend for Table
G-16 to regulate impulse noise when the standard was promulgated.
The documents we officially notice include only Labor Department publications and
scientific papers cited in documents that were introduced into evidence. Our purpose in
taking official notice is not to determine whether impulse noise is harmful or whether the
preponderance of scientific thinking in 1969 would have favored the regulation of impulse
noise under Table G-16. As we have said, weighing such evidence is not our function but
the Secretary's. Our purpose is instead to determine the intent of the Secretary in 1969
by examining the body of knowledge on impulse noise that influenced the adoption of the
standard. Because our decision rests in part on these officially-noted documents, we shall
afford the Secretary an opportunity to rebut them with documents and other evidence of his
intent when he adopted the standard.
In 1960, the Walsh-Healey standard for noise stated in its entirety: "Noise shall be
reasonably reduced or eliminated as a means of preventing fatigue or accidents." 25
Fed. Reg. 13809, 13825 (1960). In early 1964, the department proposed numerical guidelines
that would establish weekly exposure limits for "continuous steady noise" and
also establish a peak limit of 135 dB for "any exposure....however short in duration
other than impact noises. . . . " U.S Dept. of Labor, Bureau of Labor Standards,
"Suggested Language for a Noise Control Program," as printed in "Noise:
Guidelines for control issued by Bureau of Labor Standards," Safety Standards 18,
20-21, 24 (U.S. Dept. of Labor, March-April 1964 ; see also U.S. Dept. of Labor, Bureau of
Labor Standards, Suggest Language for a Noise Control Program (1965).
The Technical Committee on Noise of the American Industrial Hygiene Association
("AIHA") met in May 1964 with Jones (then of the U.S. Department of Health,
Education and Welfare) and Botsford (then employed by Bethlehem Steel, its senior noise
control engineer). The committee members believed that the newly-published guidelines had
technical errors in them and that better guidelines could be developed. The AIHA therefore
decided to offer to the Labor Department the formation of a committee of noise experts to
recommend different guidelines. The Labor Department agreed to the formation of such a
committee, which was called the Inter-Society Committee on Guidelines for Noise Exposure
Control ("Inter-Society Committee"). The committee consisted of two members from
each of five technical societies: the AIHA, the American Conference of Governmental
Industrial Hygienists ("ACGIH"), the American Academy of Ophthalmology and
Otolaryngology, the American Academy of Occupational Medicine, and the Industrial Medical
Association. One of the ACGIH representatives was Dr. Floyd Van Atta of the Labor
Department, who, according to Jones, "had primary responsibility in the noise area as
far as the Department of Labor was concerned."
The Inter-Society Committee issued a report in 1967, which it characterized as the
"first attempt to extract and condense pertinent data from various scientific
literature into a meaningful and authoritative guide." Inter-Society Committee,
"Guidelines for Noise Exposure Control," 28 Am. Indus. Hygiene J. 418, 419-22
(Sept.-Oct. 1967)(I-S). For this inquiry, it is noteworthy that the committee's guidelines
were directed at developing exposure criteria for only "steady" noise. [[9]] The
following are excerpts from the guidelines:
I. Foreward
Noise-induced hearing loss increases with both the intensity of the noise and the duration
of exposure. Generally, many years of exposure to high noise levels are required to
produce significant permanent impairment in the exposed group; however, there will be
marked differences in the hearing of individuals and in their response to noise. . . .
These Guidelines will be directed toward the prevention of that portion of the permanent
hearing loss resulting from exposure to steady noise.
III. Occupational Hearing Loss Control Program
A. Evaluation of the Noise Hazard
1. Noise Measurement.
Continuous or intermittent steady noise is readily measured by standard instruments;
impulsive noise requires special procedures not considered here. [Footnote omitted.]
2. Hazard Rating.
(a) Continuous Exposure. . . . The first two columns of Table 1. [omitted] indicate the
steady noise levels to which the various groups [of persons with hearing loss] were
exposed . . . .
(b) Intermittent and Part-time Exposure. The studies on which Table I and Figure I
[omitted] are based, dealt with men exposed to noise during a normal workday, of eight
hours' duration. . .
The report went on to explain that, although there were no long-term studies of the
effects of intermittent exposures, the results of some studies implied the "simple
rule"
that for each halving of daily exposure time, the noise levels may be increased by 5 db up
to a maximum of 115 dB . . . without increasing the hazard of hearing impairment.
The application of this rule is illustrated in the following table:
Permissible Increase in db
for Less than Eight Hours Exposure
Daily Exposure Time (Hours) |
Permissible Increase Above Eight-Hour Criterion (Decibels) |
8 | 0 |
4 | 5 |
2 | 10 |
1 | 15 |
1 1/2 | 20 |
1/4 | 25 |
Notably, the Inter-Society Committee's report did not propose any particular
permissible exposure level; for this reason, the AIHA Board found the report unacceptable
and suggested that the Inter-Society Committee be disbanded. Shortly thereafter, the ACGIH
established its own committee to develop a permissible exposure limit for noise as well as
other physical agents. Jones was chairman of this committee. The ACGIH Committee drafted a
proposed standard that was published for public comment and accompanied by an explanatory
article written by Jones, "ACGIH's Proposed Threshold Limit Value for Noise," 29
Am. Indus. Hygiene J. 537-40 (Nov.-Dec. 1968)(ACGIH). See generally Appendix A.1 to this
decision.
The most noteworthy aspect of the ACGIH Committee's proposal is that it twice stated that
its proposed limits would "not apply to impulse or impact type of noise." ACGIH
at 540 (proposed standard). Instead, the proposed standard stated, "[i]t is
recommended that exposure to this type of noise should not exceed 140 dB peak sound
pressure level." Id. Jones' article explained the ACGIH Committee's reasons for
distinguishing between continuous noise and impulse noise:
After considering [various data], the Committee decided that at the present time it
appears desirable to establish a limit of 92 dBA for 4 to 8 hours of exposure per day to
broad band continuous noise . . .
Laboratory data . . . and . . . field data indicate that, when exposure is for less than a
full 8-hour period or is intermittent in nature, the ear can tolerate more acoustical
energy per day than for a single exposure to continuous noise. Considering these two
factors, the limit is increased 5 decibels for each halving of exposure time. The exposure
time is the summation of the exposure periods for the work day regardless of whether this
is a single exposure or an exposure which is intermittent in nature.
Very little data is available upon which to base exposure to impact or impulsive noise. It
is known that exposure to a small number of 140 dB impulsive noises of short duration will
produce a temporary threshold shift. Until additional data is available, a limit of 140 dB
is being set for impact or impulsive noise.
ACGIH at 538 (article)(references omitted).
Thus, the criteria proposed by both the Inter-Society Committee and the ACGIH Committee
excluded impulse noise, with the exception of the ACGIH proposal for a peak limit of 140
dB for impulse noise. The reason they otherwise excluded impulse noise was apparently
because, as stated in Jones' article, "[v]ery little data is available upon which to
base exposure to impact or impulsive noise." Both the Inter-Society Committee and the
ACGIH Committee had cited a number of scientific studies completed by the late 1960's that
attempted to measure the effect of noise on human hearing. These studies, which are
excerpted in the appendix to this decision, had measured hearing loss caused by various
degrees of noise exposure. Because most of them involved purely steady-state noise, they
formed a substantial body of evidence from which permissible exposure limits and an
exchange rate--the number of decibels by which sound levels could rise if exposure time
was halved--could be derived. However, there was considerably less evidence on which to
base permissible exposure limits to impulse noise. The scientists who attempted to develop
hearing protection criteria cautioned against applying them to impulse noise, and tended
to regard impulse noise and continuous noise as two distinct problems. The studies cited
by the Inter-Society Committee and the ACGIH Committee dealing with "steady"
noise primarily attempted to determine a safe eight-hour exposure level and an exchange
rate that represented an appropriate trade-off of higher intensity for a shorter time.
Studies of the harmful effects of impulse noise, by contrast looked for hearing protection
criteria in terms of factors such as the peak intensity, total number of impulses, and
duration of impulses. Thus, the criteria proposed for "steady" noise cautioned
against application to impulse while criteria for impulse noise would not, by their very
nature, apply to steady noise. See generally Appendix A.2 - A.7.[[10]]
On September 20, 1968, the Labor Department published a proposed standard to regulate
workplace noise exposure. 33 Fed. Reg. 12458, 14259-60. This proposed standard bore very
little resemblance to the present standard. It basically established a weekly average
exposure limit of 85 dB for "steady (or equivalent) noise" and included impulse
noise in its exposure calculations. It spoke of noise with "intervals . . . more than
one second and . . . maxima less than 1 second each," which fits the definition of
impulse noise. The proposed standard provided that such noise maxima are to be included in
the exposure calculations as if they had durations of 1 second each. See generally
Appendix A.B.
The proposal was unfavorably received in the industrial hygiene community. Despite this,
on January 17, 1969, a few days before President Johnson's term expired, the Labor
Department issued a package of Walsh-Healey standards, including a noise standard very
similar to that which had been proposed. 34 Fed. Reg. 788, 790-91. The promulgated
standard retained the exposure limit of the proposed standard and the provision that dealt
with impulse noise.
Before the promulgated standard became effective, it was stayed by the new Secretary of
Labor. 34 Fed. Reg. 2207 (1969). On May 20, 1969, the Labor Department issued a new noise
standard that differed radically from the earlier one. 34 Fed. Reg. 7946, 7948-49. Except
for some subsequent corrections (35 Fed. Reg. 1015 (1970)) , the new standard is identical
to the one at issue in this case . Major differences between the earlier standard and the
later standard include provisions relevant to the impulse noise issue. The earlier
standard explicitly stated that noise with maxima less than one second in duration and
greater than one second apart, i.e., impulse noise, was to be included in weekly exposure
calculations. However, the final standard contained no similar provision and included a
provision with no counterpart in the earlier standard-- a recommended limit of 140 dB for
impulse noise.
The final standard strongly resembled that adopted by the ACGIH on May 12, 1969, eight
days before the final version of the Walsh-Healey standard was adopted.[[11]] Jones was
still the chairman of the ACGIH Committee; he stated that Dr. Van Atta of the Labor
Department had been aware of the workings of the Committee and of its proposed standard,
and that he had received advance copies of the final ACGIH standard. Relevant excerpts
from the ACGIH standard follow:
Threshold Limit Values Noise
Continuous or intermittent
The sound level shall be determined by a sound level meter . . . operating on the
A-weighting network with slow meter response. Exposure shall not exceed that shown in
Table 1
Table 1
Permissible Exposures
Duration per Day Hours |
Sound level dB(A) |
8 | 90 |
6 6 |
92 t |
4 | 95 |
3 | 97 |
2 | 100 |
1 1/2 | 102 |
1 | 105 |
3/4 | 107 |
1/2 | 110 |
1/4 | 115-C** |
11ACGIH, "Threshold Limit Values of Physical Agents" (1969), reprinted in
Fundamentals of Industrial Hygiene, Appendix A
*Sound level in decibels as measured on a standard level meter operating on the
A-weighting network with slow meter response.
**Ceiling Value
___________________________
These values apply to total time of exposure per working day regardless of whether this is
one continuous exposure or a number of short-term exposures but do not apply to impact or
impulse type of noises.
When the daily noise exposure is composed of two or more periods of noise exposure of
different levels, their combined effect should be considered, rather than the individual
effect of each. If the sum of the following fractions:
C1/T1 + C2/T2 + ....... Cn/Tn
exceeds unity, then, the mixed exposure should be considered to exceed the threshold limit
value, C1 indicates the total time of exposure at a specified noise level, and T1
indicates the total time of exposure permitted at that level . . .
Impulsive or impact noise
It is recommended that exposure to impulsive or impact noise should not exceed 140
decibels peak sound pressure level-C
This ACGIH standard is very similar to the Walsh-Healey standard ultimately promulgated by
the Secretary of Labor. Indeed, the final Walsh-Healey standard was much closer to the
ACGIH standard than it was to the earlier Walsh-Healey standard that is supplanted. In
particular, the most important part of the final Walsh-Healey standard, the table listing
the permissible exposure limits, almost identical to the corresponding table in the ACGIH
standard. The passages on impulse noise and the cumulation formula are also nearly
identical to those in the ACGIH standard. In light of the similarities between the two
final standards, and of Jones' testimony that Dr. Van Atta of the Labor Department was
familiar with the proceedings of the ACGIH Committee and had advance copies of its work
products, we infer--as do both the Secretary and Collier-Keyworth--that the final ACGIH
standard heavily influenced the final Walsh-Healey standard.[[12]]
The Walsh-Healey standard does not state explicitly that impulse noise is excluded, as
does the ACGIH standard, and the absence of such a statement in the Walsh-Healey standard
might be taken to mean that the Secretary rejected this aspect of the ACGIH standard,
deciding to include impulse noise in Table G-16 calculations. However, the final
Walsh-Healey standard also does not state explicitly that impulse noise is included in
such calculations. In this critical respect, it departed from the earlier Walsh- Healey
standard, which expressly included impulse noise. Moreover, the final Walsh-Healey
standard contained the impulse noise provision and subsection (b)(2), both of which
suggest that impulse noise was to be excluded from Table G-10.
Although we cannot determine solely from the standard's legislative history to this point
whether the Secretary intended impulse noise to be included in Table G-16 calculations, it
does reveal several highly significant facts: Many of the scientists and organizations
whose attempts to develop criteria for noise were cited by the ACGIH Committee and the
Inter-Society Committee did not believe it either necessary or appropriate for the
criteria they developed for steady or continuous noise to apply to impulse noise. Indeed,
it appears that the preponderant thinking in the scientific community that was cited by
the ACGIH Committee and the Inter-Society Committee was to exclude impulse noise from
criteria for steady noise. The Labor Department was evidently aware of this, for its
technical expert on noise served on the Inter-Society Committee and was aware of the views
of and the limits developed by the ACGIH Committee. The standard it adopted drew heavily
on the work of the ACGIH Committee and, indirectly, that of the Inter-Society Committee.
There is also strong evidence that the Department of Labor agreed with the body of
scientific opinion cited by the ACGIH Committee and the Inter-Society Committee.
On December 4, 1970, after the noise standard was adopted under the Walsh-Healey Act, the
Labor Department's Bureau of Labor Standards published Bulletin
334 , Guidelines to the Department of Labor's Occupational Noise Standards for Federal
Supply Contracts (Dec. 4, 1970), a detailed manual explaining to government contractors
what their duties were. The 1970 version [[13]] of Bulletin 334 states in part:
Table 1 [equivalent to Table G-16] indicates [excessive noise] ....... Employees must not
be exposed to steady sound levels above 115 dBA, regardless of the duration.
........The "slow" response [on the sound level meter] is another setting
........ . which causes it to average out high level noise of brief duration (such as
hammering), rather than responding to the individual impact noises.
Impulse or Impact Noise
The last sentence in paragraph (d) of section 50-204.10 states:
"Exposure to impulsive or impact noise should not exceed 140 dB peak sound pressure
level."
This sets the upper limit of sound level to which a person should be exposed, regardless
of the brevity of the exposure.
In contrast with the 115 dBA upper limit for steady noise, the higher intensity for impact
noise is permissible because the noise impulse resulting from impacts, like hammer blows
or explosive processes, is past before the ear has time to react fully. Impact noise
levels are to be measured only with an impact meter or an oscilloscope.
Variable Noises
Paragraph (c) of section 50-204.10 states the final consideration in determining whether
or not a permissible sound level is being exceeded:
"(c) If the variations in noise level involve maxima at intervals of 1 second or
less, it is to be considered continuous."
This means that where the sound level meter on the A scale at slow response moves up from
a generally steady reading, say from 88 to 92 dB, at intervals of one second or less, the
high reading shall be taken as that to be used in Table 1 [equivalent to Table G-16].
As a corollary to this, intermittent sounds of brief duration at intervals greater than
one second should, as far as practical, be measured as to intensity and duration and the
total duration over a day be ascertained. This total should be entered in the equation
given in footnote 1, Table 1, to determine the permissible limit. These intermittent
sounds, which can be measured with a sound level meter, should not be confused with
impulse sounds of very short duration resulting from impacts or explosions.
Id. at 2, 6-7 (emphasis added).
Bulletin 334 went on to state that noise levels were to be measured with a sound level
meter, set for A scale and slow response, meeting the specifications for sound level
meters established by the American National Standards Institute (ANSI) in ANSI S1.4-1961,
"Specification for General- Purpose Sound Level Meters." Bulletin 334 at 14.
This ANSI standard contains the following provisions:
Introduction
It should also be recognized that the ballistics and other characteristics of the
indicating instrument are adapted mainly for measuring ordinary machinery noises and other
sounds of a reasonably constant character. For intermittent sounds, and more particularly
for repetitious sounds involving high peak-to-average ratios in sound pressure, and for
impact noises, other specialized equipment will be required in place of the ordinary
indicating instrument.
ANSI S1.4-1961 at p. 6 (emphasis added).
Several significant points emerge from Bulletin 334. The explanation of why a higher peak
level. is permitted for impulse noise than for steady noise-that the ear does not react
fully to impulse noise--supplies a reason why impulse noise would be excluded from Table
G-16. The statement indicates that the Secretary was aware of the scientific reasons why
the investigators who had developed criteria by 1969 for steady noise did not apply their
criteria to impulse noise. The instruction in Bulletin 334 about including
"intermittent sounds of brief duration" in dosage calculations, coupled with the
caveat against confusing such sounds with impulse noise, is tantamount to an explicit
statement that impulse noise is to be excluded from such calculations. Finally, the
provision in ANSI S1.4-1961 that standard sound level meters cannot be used to measure
impulse noise, together with the statement in Bulletin 334 that sound level meters used
for noise surveys must conform to ANSI S1.4-1961, is a further indication that impulse
noise is excluded from the standard except for the 140 dB peak level provision.[[14]]
C. OSHA's Enforcement and Later Interpretations
The record also shows that it was OSHA's practice to exclude impulse noise from Table G-16
calculations when enforcing the standard. Anne Hart, the OSHA
industrial hygienist who inspected Collier-Keyworth's plant, answered "no" when
asked, "[y]ou are not supposed to include impulse noise in your dosimeter or sound
level meter measurements, are you?" Thomas Rockwell, an expert in noise measurement
and control and a consultant to numerous corporations, testified that he wrote a letter to
the Cleveland Area Office of OSHA asking if he was correct in understanding that the
standard excluded impulse noise, and received in response a phone call from Fred Boelter,
an industrial hygienist in the Chicago office, confirming that understanding. We also note
that Dr. John Barry, a noise expert employed by OSHA since 1976, wrote in a paper
presented at Purdue University in 1979: "This standard [29 C. F. R. § 1910.95
(a)-(b)] sets the permissible exposure level for non-impulse noise at 90 dBA for an
8-hour-per-day duration and less than or equal to 140 dB peak sound pressure level for
impulse noise irrespective of its duration."[[15]]
Dr. Barry also was the principal author of a document instructing OSHA industrial
hygienists in the proper techniques for determining compliance with the standard. This
document was first published on April 2, 1979, as OSHA Instruction CPL 2-2.20 and was
later incorporated in OSHA's Industrial Hygiene Field Operations Manual
("IHFOM") as Chapter IV.[[16]] Section C.1.e provided:
Where both continuous and impulse noise are present, measure the background on the dBA
fast mode to determine if the continuous noise is above the levels found in Table G- 16,
29 C. F. R. §1910.95.
Thus, OSHA instructed its inspectors to determine whether the continuous component alone
in a mixture of continuous and impulse noise exceeded the limits of Table G-16. Hart's
acknowledgment that she was not supposed to include impulse noise in dosage measurements
therefore reflected an official, agency-wide practice [[17]]
Our understanding of OSHA's early enforcement practices is further aided by OSHA's
comprehensive proposal in 1974 to completely replace section 1910.95 with a more precise
standard. The standard that OSHA then proposed and the explanation accompanying it
indicate that OSHA did not view the existing standard as including impulse noise in dosage
calculations. The proposed standard would have retained the 90 dBA limit in the existing
standard but would have coupled that limit with requirements for a stringent hearing
conservation program when the eight-hour time weighted average noise level exceeded 85
dBA. 39 Fed. Reg. 37773, 37774 (Oct. 24, 1974). Although OSHA proposed to retain the 90
dBA limit at which engineering controls, administrative controls, and personal protective
equipment were required, it proposed to draw a sharp distinction between steady-state
noise and impulse noise, explicitly excluding the latter from dosage calculations. The
proposed standard provided in part:
§ 1910.95 Occupational noise exposure.
(c) Permissible exposure limits.
(1) Steady state noise---single level. (i) The permissible exposure to continuous noise
shall not exceed an eight-hour time-weighted average of 90 dBA with a doubling rate of 5
dBA. For discrete permissible ...... limits, refer to Table G-16a [omitted, similar to
Table G-16].
(ii) Where Table G-16a does not reflect actual exposure times and levels, the permissible
exposure to continuous noise at a single level shall not exceed [an amount determined by a
given formula] where "L" is the workplace sound level measured in dBA on the
slow scale of a standard sound level meter....
(2) Steady state noise--two or more levels. Exposures to continuous noise at two or more
levels may not exceed [a dose computed by the cumulation formula] where C is the actual
duration of ...... a given steady state noise level ......
(3) Maximum steady state noise level. Exposure to continuous noise shall not exceed 115
dBA ......
(4) impulse or impact noise. (i) Exposures to impulse or impact noise shall not exceed a
peak sound pressure level of 140 dB.
(ii) Exposure to impulses of 140 dB shall not exceed 100 such impulses per day. .......
For each decrease of 10 dB in the peak sound pressure level of the impulse, the number of
impulses to which employees are exposed may be increased by a factor of 10.
39 Fed. Reg. at 37775. The preamble to the proposed standard explained why OSHA proposed
to treat impulse noise in this way:
The present OSHA standard recommends that impact or impulse sounds not exceed a peak sound
pressure level of 140 dB. The Advisory Committee suggested that this limit be made
mandatory. OSHA. has made an addition to the Advisory Committee's recommendation with
respect to impulse noise exposure, because the actual exposure is a summation of the peak
sound levels of the impulses and the number of impulses. OSHA proposes to limit exposure
to impulses at 140 dB to 100 per day and to permit a tenfold increase in the number of
impulses for each 10 dB decrease in the peak pressure of the impulse. For example, the
number of impulses allowed at 130 dB would be 1,000 per day and the number of impulses
allowed at 120 dB would be 10,000 per day.
39 Fed. Reg. at 37774. Although the proposed standard thus specified separate exposure
limits for steady-state noise and impulse noise, its preamble gave no indication that OSHA
considered the proposed standard a departure from the existing standard. Indeed, its
explanation of the proposed standard indicates that OSHA viewed the 140 dB peak limit as
being the only provision in the existing standard addressed to impulse noise. While this
falls somewhat short of being a formal interpretation of the existing standard, it
supplements the other evidence tending to show that OSHA had interpreted the existing
standard to exclude impulse noise from Table G- 16.
The Secretary asserts that it was not his customary practice to exclude impulse noise from
Table G-16. He cites Turner Co., 76 OSAHRC 108/A2, 4 BNA OSHC 1554, 1976-77 CCH OSHD (P)
21,023 (No. 3635, 1976). rev'd on other grounds, 561 F.2d 82 (7th Cir. 1977), as an
example of a case where a citation based on impulse noise from power presses was issued
and affirmed. Turner does not support the Secretary's argument. The impulse noise issue
was not raised in Turner and the parties stipulated that the noise levels exceeded those
permitted by Table G-16. 4 BNA OSHC at 1556, 1976-77 CCH OSHD at p. 25,274. Moreover,
power press noise is not inevitably impulse noise. If the noise maxima occur more
frequently than once per second, a situation that may well have been the case in
Turner,[[18]] the noise is defined as continuous by subsection (b)(2) of the standard. In
any event, even if Turner did involve impulse noise, a single citation does not show an
enforcement policy and does not rebut the otherwise overwhelming evidence that OSHA
interpreted the standard to exclude impulse noise from Table G-16.
Bulletin 334 is nearly contemporaneous with the adoption of the standard, consistent with
OSHA's early enforcement policy, and therefore likely to reflect the understanding of
those in OSHA who drafted the standard. We cannot, however, say the same of the arguments
in the Secretary's brief. The Commission has generally not considered interpretations of
standards in the Secretary's briefs to be authoritative. E.g., C. F. & I. Steel Corp.,
86 OSAHRC _____, 12 BNA OSHC 2067, 2074, 1986 CCH OSHD (P) 27,691, pp. 36,139-40 (No.
79-4786, 1986). It has long been the experience of the Commission that interpretations
advanced before the Commission in the Secretary's briefs often are interpretations made to
support litigation positions. They are not necessarily interpretations traceable to the
intent of the standard's drafters. Id.; see Investment Company Institute v. Camp, 401 U.S.
617, 626-28 (1971)(counsel's efforts in litigation are "hardly tantamount to an
administrative interpretation" of a statute). This is a vital distinction, for it is
the drafters of a standard who incorporate into it the policies and compromises that the
rulemaking record demonstrates are appropriate. To give weight to an administrative
interpretation not traceable to the standard's drafters would effectively permit the
Secretary to amend the standard without the safeguards mandated by Congress to afford
persons affected by the standard an opportunity to participate in the rulemaking process.
The brief the Secretary filed in this case gives us no reason to believe that the
interpretation it advances is traceable to the intent of the drafters. The brief does not
address subsection (b)(2) of the standard and its use of the word "continuous."
It does not mention Bulletin 334, or the 1974 proposed standard and its preamble. It does
not purport to have been written or reviewed by lawyers who consulted with the drafters of
the standard or who participated in the drafting of the standard. The brief does address
the 140 dB impulse noise provision but misapprehends the events that lay behind its
adoption. See note 12 above. It also relies on the testimony adduced in this litigation on
the harmfulness of impulse noise and alludes to the findings OSHA made in 1981 to support
the hearing conservation amendment, though neither is evidence of what the Secretary
intended when he adopted section 1910.95(a)-(b). In sum, the Secretary's brief reflects
OSHA's current appreciation of impulse noise but provides no insight into what the
Secretary of Labor intended in 1969. It is therefore entitled to no weight here.
Bulletin 334 and the Secretary's early enforcement policy are entitled to considerable
weight, however. Bulletin 334 is "a nearly contemporaneous interpretation of the
standard by its drafter." Wheeling-Pittsburgh Steel, 11 BNA OSHC at 1294, 1983-84 CCH
OSHD at p. 33,673. Its view that impulse noise is to be excluded from Table G-16
calculations is also reflected in OSHA's original enforcement policy and the understanding
of OSHA officials in the 1970's, such as Dr. Barry, who were responsible for the
standard's enforcement. And it is consistent with the rationale behind the 1974 proposed
standard, a document that explicitly established separate limits for impulse noise and
steady-state noise and gave no hint that OSHA viewed this as a departure from the current
standard.
The Secretary argues that exclusion of impulse noise "is fundamentally inconsistent
with [the standard's] goal of safeguarding human hearing." That a standard addresses
a problem does not mean that it was intended to safeguard employees from it entirely.
Drafters may lack enough information to justify a comprehensive treatment or to know even
how to write a comprehensive standard. They may therefore decide to regulate a step at a
time, going as far as their knowledge carries them and leaving the rest for another day.
That happened here. From its text and legislative history, from Bulletin 334 and OSHA's
early enforcement policy, we find that the drafters of section 1910.95(a)-(b) intended to
exclude from Table G-16 impulse noise--that is, noise with sharp energy peaks lasting less
than one second and spaced more than one second apart. We therefore vacate citation items
1a(B) and (D), and 1b(B) and (D), which are based on exposure readings of employees
exposed to impulse noise.
III. Noise Exposure of Employees
The Secretary alleges that Collier-Keyworth employees were exposed to noise in excess of
the standard's limits and that the company did not take the precautions required by the
standard to protect the employees. The record shows that the noise to which
Collier-Keyworth's employees were exposed consisted of a mixture of noise from the
machines on which they were working and background noise that was present even when their
machines were not operating. The background noise was purely continuous noise, i.e., noise
of unvarying or slowly varying intensity. The machine noise basically falls into two
categories:(1) purely impulse noise, i.e., noise with sharp energy peaks spaced at
intervals greater than one second; and (2) noise resulting from impulses spaced less than
one second apart, which is defined as continuous by the standard and which, for the sake
of convenience, we shall call "quasi-continuous" noise. To prove over-exposure,
the Secretary introduced into evidence dosimeter readings that measure an accumulated
dosage from all noise present in the work environment, including impulse noise. We have
concluded, however, that pure impulse noise must be excluded from measurements to
determine compliance with Table G-16. Thus, in evaluating the dosimeter readings
introduced by the Secretary, we must determine whether they were contaminated by
sufficient impulse noise to render them unreliable measures of compliance with Table G-16
levels. We find, for the reasons discussed in below, that some samples were so
contaminated but that others were not, for they registered quasi-continuous noise.
Collier-Keyworth also argues, however, that dosimeters do not reliably measure
quasi-continuous noise.
A. The Use of Dosimeters to Measure Quasi-Continuous Noise
Collier-Keyworth argues, and Judge Furcolo agreed, that in impulsive noise environments,
the dosimeters used by OSHA may not be relied on to prove violations of Table G-16
exposure limits because they indicate noise levels significantly higher than the
"true noise levels." In making this argument, the company does not distinguish
between pure impulse noise and quasi-continuous noise.
Such a distinction must be made, however, Although pure impulse noise must be excluded in
determining compliance with table G-16, quasi-continuous noise is included. Dosimeter
readings in environments containing significant amounts of pure impulse noise are
inherently unreliable regardless of the accuracy with which they measure impulse noise,
for they should not be measuring such noise at all. They should, however, be measuring
quasi-continuous noise, and the accuracy with which they measure this type of noise is
critical. Thus, we must consider Collier- Keyworth's argument to the extent it questions
the accuracy with which OSHA's dosimeters measure quasi-continuous noise.
We will assume in this discussion that ColIier-Keyworth is correct in its assertion that
dosimeters in impulsive noise environments register dosages as if noise level's were
significantly higher than the "true noise levels."[[19]] However,
Collier-Keyworth's argument cannot logically be seen as merely an objection to dosimeters
but to the standard's prescription of the slow response mode of measurement. As we have
said, a noise dosimeter is in effect a sound level meter with additional circuitry that
automatically records dosages in the manner set out in the cumulation formula of Table
G-16. And, as we shall discuss below, the circuitry of a dosimeter that arguably causes it
to overcount "true noise" levels is not its additional dosage- calculating
circuitry but the slow response circuitry it shares with conventional sound level meters.
Thus, despite the emphasis in Collier-Keyworth's brief on the inability of dosimeters to
reliably detect "true noise levels," its argument could apply with equal force
to conventional sound level meters. Indeed, Collier-Keyworth's acoustical engineering
expert. Thomas Rockwell, admitted that he would obtain the same results using a slow
response sound level meter as a slow response dosimeter.
Dosimeters and sound level meters employing slow response seem to overcount the "true
noise level" because slow response instruments have an integration time of one
second, that is, they register an impulse as if it were spread out over a second. A burst
of sound lasting one-half second would therefore be displayed as if it were one second
long. Because the slow response integration time is longer than the duration of such a
noise impulse, the slow response mode distorts the "true" noise pattern, making
impulses appear longer in duration but lower in peak intensity.[[20]]
Collier-Keyworth argues that the net effect of the slow response mode is to cause
dosimeters to read higher than the "true noise level." The problem with
CoIlier-Keyworth's argument is that section 1910.95(a)-(b) does not regulate "true
noise levels." The standard regulates sound levels (1) as measured by a standard
sound level meter, (2) as detected by slow response, (3) as weighted by frequency
according to the A-weighting network (which weights each sound frequency according to the
ear's response to it), (4) excluding impulses more than a second apart, and (5) treating
impulses less than a second apart as continuous. Indeed, it is rather pointless to speak
of "true noise levels" because they can never be measured. To measure "true
noise levels" would require an ideal instrument having, among other things, an
instantaneous response time, that is, an integration time of zero. One could build a sound
level detector with a short response time, perhaps an eighth of a second, as fast response
instruments have. But such an instrument would still not be measuring "true noise
levels."
Inasmuch as section 1910.95(a)-(b) does not regulate "true noise levels" but
levels as detected by slow response instruments, Collier-Keyworth's argument is really a
complaint about the standard's prescription of slow response. Collier-Keyworth seems to
desire that sound level meters and dosimeters be employed at fast response so as to more
closely approximate the "true level" of impulse noise.[[21]] However, the
standard specifies the use of slow response and whatever deviations from true noise levels
that mode introduces were within the contemplation of its drafters. That slow response
instruments give greater weight to impulse noise than fast response instruments must be
regarded as one of the many compromises that the Secretary struck when he adopted the
standard. Just as the Secretary could provide that impulses recurring at greater than
one-second intervals not be counted at all, he could provide for a measurement technique
that gives additional weight to impulses closer than one second together.
Collier-Keyworth does not point to any illegality in the Secretary's choice of slow
response.[[22]] We therefore reject Collier-Keyworth's arguments that slow response
dosimeters may not be used to detect exposures greater than those permitted by Table G-16.
[[23]]
B. Evidence of Exposure
We now consider whether OSHA proved that any Collier-Keyworth employee was over-exposed to
quasi-continuous noise. On April 14, 1980, OSHA industrial hygienist Anne Hart began an
inspection of Collier-Keyworth's plant aimed at determining whether the company was in
compliance with the noise standard. Hart attached General Radio Model 1954 dosimeters to
five Collier-Keyworth employees, who wore the dosimeters throughout their work day. One of
the dosimeters malfunctioned, and Hart returned on April 18 to obtain a dosimeter reading
for that employee. Hart also measured the noise levels in the employees' hearing zones at
various times throughout the inspection by using a sound level meter. The employees who
were sampled operated power presses and lathes in four different areas of the plant.
Presses 2208, 2209, and 2210 (citation items 1a(A)) and 1b(A)) are 60-ton Bliss open-back
inclinable power presses used by Collier-Keyworth to fabricate metal parts. The presses
operate automatically. Sheet steel is fed into the press bed by a feeder mechanism. A die
attached to a ram above the bed descends and stamps the part out of the stock. The part is
removed from the bed by high-speed air blown out of nozzles. The three presses were
located within ten feet of each other.
The presses were operated by Paul LeBlanc and Norman Melanson. The operators' duties
including changing dies, making necessary adjustments, installing coils of sheet steel
stock, threading the stock into the die area, and monitoring the operation of the presses.
An operator had to be in the general area of the machines while they were operating, but
the operation of each machine did not have to be monitored closely.
Using a sound level meter, Hart measured noise levels in the vicinity of the presses
ranging from 85 to 104 dBA, with readings below 90 dBA occurring only when none of the
presses were operating. The dosimeter worn by LeBlanc read 305% it the end of the day, and
that worn by Melanson read 286%. These readings indicate that both employees were exposed
to approximately three times the permissible dose, or, viewed a different way, that they
were exposed to time-weighted average sound levels of about 97.6 dBA and 98.0 dBA. See 29
C.F.R. § 1910.95, Appendix A, Table A-1 (hearing conservation standard). Hart testified
that she timed the presses using a watch with a second hand and found that the impacts for
each machine were less than one second apart. She also stated that the strokes of the
three machines were not synchronized, so that when all three presses were running, the
noise peaks were less than one-third second apart.
Collier-Keyworth's chief engineer, Robert Cochran, testified that the presses had a
maximum stroke rate of 80 per minute. The actual stroke rate was controlled automatically
by the feeder mechanism and was different for each part being produced. Each machine was
used to produce about 30 different parts. Cochran did not know the stroke rates that
corresponded to the various parts.
Following the inspection, noise measurements were made in Collier-Keyworth's plant by
experts for both parties: Thomas Rockwell for Collier-Keyworth and John Barry for the
Secretary. Both experts fed the output from sound level meters into strip-chart recorders,
which draw tracings showing how the noise level's fluctuate with time. Tracings made by
Rockwell on June 17, 1980, show press 2208 operating at 57.5 strokes per minute, press
2209 at 48 strokes per minute, and press 2210 at 56 strokes per minute. Rockwell testified
that Cochran told him that the presses were producing some of the same parts they had been
making on the day of Hart's inspection.
Under subsection (b)(2) of the standard, noise that consists of a series of impulses less
than one second apart is treated as continuous. This quasi continuous noise will be
produced by a press operating at a stroke rate of more than one per second, or sixty per
minute. A press stroking slower than once per second will, however, generate impulse
noise. Collier-Keyworth's presses can stroke as fast as eighty per minute, but the actual
rate depends on the part being produced and for some parts is slower than sixty per
minute. Collier-Keywortn's presses therefore generate quasi-continuous noise at certain
times and impulse noise at other times
The evidence shows that LeBlanc and Melanson were exposed only to quasi-continuous noise
on the day of the inspection. Hart testified that she timed the presses and that the time
between strokes was less than one second for each press. There is no evidence directly
contradicting Hart's testimony.[[24]] Collier-Keyworth production records showing the
parts produced on the day of the inspection were introduced into evidence, but the company
presented no evidence on the stroke rates that corresponded to those parts.
Collier-Keyworth did show that on a later date, when Rockwell measured the noise from its
presses, the presses were stroking slower than once per second, indicating that the noise
at that time was impulse noise. Moreover, Rockwell testified that Cochran had told him
that the presses were producing some of the same parts when he was in the plant as when
Hart made her inspection. However, Rockwell spent parts of three days in the plant, and
the production records introduced into evidence show that the presses typically produced
different parts on different days. Therefore, during the three days Rockwell was in the
plant, the presses probably produced several different parts each, including some that
were made during Hart's inspection and others that were not. In the absence of evidence
that the parts produced when Rockwell made the strip chart recordings showing the presses
operating slower than once per second were the same as those manufactured during Hart's
inspection, Rockwell's testimony does not contradict Hart's evidence that the presses were
stroking faster than once per second.
We also note that it is not the noise generated by a machine, but the noise heard by an
employee, that the standard regulates. During most LeBlanc's and Melanson's workday, two
or three presses were operating and generating noise. As the presses were not
synchronized, the noise maxima that they heard would have occurred about twice per second
with two presses running and about three times per second with three presses operating. In
any event, because each press individually produced quasi-continuous noise, two or three
presses operating at individually produced quasi- continuous noise, two or three presses
operating at the same time would also produce quasi- continuous noise.
Because LeBlanc and Melanson were exposed only to quasi-continuous noise, their dosimeter
readings did not include any measurements of impulse noise. Those dosimeter readings--305%
for LeBlanc and 286% for Melanson--facility indicate exposure that exceeds permissible
limits. Collier- Keyworth asserts that a number of factors can affect dosimeter readings,
including electromagnetic fields or radio waves, wind, orientation of the microphone,
chemicals, temperature effects, moisture, and noise made by the employee wearing the
dosimeter. There is no evidence, however, that any of these factors significantly
distorted the dosimeter readings made during the OSHA inspection of Collier-Keyworth's
plant. The dosimeter readings obtained by industrial hygienist Hart are consistent with
sound level meter readings she made on the day of the inspection as well as with
measurements made on later days by Rockwell and Barry. Hart measured the noise level in
LeBlanc's hearing zone to be 99-102 dBA when LeBlanc was standing by press 2208 with
presses 2208 and 2209, but not 2210, operating. When Melanson was standing beside press
2209 with 2208 and 2209 running, the noise level was 100-104 dBA.[[25]] At certain times,
Hart measured noise levels below 90 dBA for both LeBlanc and Melanson with none of the
presses running. Hart noted, however, that all three presses were usually running during
her inspection. Also, chief engineer Cochran testified that Collier-Keyworth had no excess
press capacity, indicating that the presses operated full-time except when dies were
changed or adjustments made.
As noted above, the dosimeter readings Hart obtained for both LeBlanc and Melanson were
approximately 300% of the permitted daily dose. An employee exposed to a constant noise
level of 100 dbA for 6 hours would receive a dosage of 300%. The sound level meter
readings made by Hart show that LeBlanc and Melanson were sometimes exposed to noise
levels less than 90 dBA, out were exposed to noise levels around 100 dBA for most of their
8-hour shifts. Thus, the sound level meter readings tend to show that the dosimeters were
accurately measuring and recording the noise levels to which LeBlanc and Melanson were
exposed.
In summary, we conclude that on April 14, 1980, LeBlanc and Melanson, the operators of
presses 2208, 2209, & 2210, were exposed to noise in excess of the limits permitted by
Table G- 16.
Press 2216 (items 1a(C) and 1b(C)) is a 60-ton Bliss press similar to the three presses
discussed in the previous section but located some distance from them. In April 18, 1980,
industrial hygienist Hart attached a dosimeter to press operator Alan Sund. After 202
minutes, or about 3.3 hours, the dosimeter read 167%. Sound level meter readings made by
Hart in Sund's hearing zone at four different times over the period the dosimeter was
operating were 103-107 dBA while the press was running. Sund was then observing the
machine from a distance of one to two feet. As with the other presses, Hart testified that
she timed the stroke rate and that the time between strokes was less than one second. On
June 17, 1980, Rockwell measured the stroke rate of the press to be 45 strokes per minute,
but there is no evidence that the press was producing the same part, and thereby running
at the same speed, as during Hart's inspection.
For much the same reasons as previously discussed, we find that the evidence shows Sund
was exposed to noise exceeding the standard's permitted limits. Hart's testimony that the
time between strokes was less than one second on the day the inspection establishes that
the noise was continuous within the meaning of the standard. The dosimeter reading
facially indicates that Sund was exposed to excessive noise. The sound level meter
readings indicated that Sund was exposed to 103-107 dBA for about 3.3 hours. At 103 dBA,
the lowest sound level or this range, only about 1.3 hours of exposure is permitted. Thus,
the sound level meter readings corroborate the measurement of excessive exposure made by
the dosimeter.
Press 352 (items 1a(D) and 1b(D)) is a manually-fed machine used for small bending jobs.
On April 14, 1980, Hart obtained a reading of 256% from a dosimeter attached to press
operator Ernest Couture. According to Hart, the press strokes once every two or three
seconds. With the machine not operating, Hart measured the noise in Couture's hearing zone
to be from 84 to 88 dBA. With the machine operating, she measured noise levels as high as
95 dBA.
We conclude that the Secretary did not prove Couture was exposed to excessive noise.
Because the press stroked only once every two to three seconds, the noise that resulted
from the press's operation was impulse noise, which is not regulated by Table G-16. The
only continuous noise to which Couture was exposed was background noise measured to be 84
to 88 dBA, levels within the standard's limits for any exposure time. We therefore find
that Couture was not exposed to noise exceeding the standard's limits and we will vacate
Items 1a(D) and 1(b)(D)).
Lathes 6040 and 3018 (items 1a(B) and 1b(B)) are used to cut metal tubing and chamfer the
ends. Both lathes were operated by a single employee, Ken Thompson. Lathe 6040 was
operated manually, while lathe 3018 was automatic. Therefore, when both lathes were
operating, Thompson would be standing beside lathe 6040. On April 14, 1980, a dosimeter
attached to Thompson during his shift yielded a reading of 158.5%. According to sound
level meter readings made by industrial hygienist Hart, the noise level in Thompson's
hearing zone ranged from 85 to 107 dBA.
Lathe 6040 was relatively quiet and, when operated alone, produced noise levels below 90
dBA. Thus, the noise that caused the standard's limits to be exceeded was generated by
lathe 3018. That lathe sometimes emitted a very loud high-pitched squeal, but at other
times the squeal was missing. Hart recorded noise levels of 107 dBA when the squeal was
evident, but only 92 dBA with both lathes running but no high-pitched squeal present. When
Dr. Barry later visited Collier- Keyworth's plant, he measured 118 dBA in the hearing zone
of the operator of lathe 3018. Upon analyzing the frequencies contained in the noise,
Barry found that the excessive noise primarily occurred at 8000 hertz and higher,
frequencies which the human ear would perceive as very high.
Both Barry and Rockwell made strip chart recordings of the lathe noise. These recordings
show very pronounced short bursts of noise, much like the strip chart recordings for the
power presses. The charts are not labeled with time scales that would enable the time
between bursts to be measured, but Rockwell testified that the charts show a peak-to-peak
separation greater than one second, indicating that at least some of the noise is impulse
noise.
We conclude that the Secretary failed to prove Thompson was exposed to excessive noise.
Some of the noise to which Thompson was exposed, and which was detected by the dosimeter,
was impulse noise that must be excluded under the standard. There is no basis to conclude
that Thompson's dosimeter reading would have shown overexposure if the impulse noise had
been excluded. Indeed, it is doubtful that the Secretary proved overexposure even assuming
that impulse noise were to be included. Industrial hygienist Hart testified that Type 2
sound level meters and dosimeters, the type she used in her inspection, generally have an
inherent error factor of two dBA; when that error is cumulated over time, it creates a
potential error of 32% in the dosimeter reading.[[26]] Thus, a dosimeter reading of
158.5%, as was obtained for Thompson, would generally be outside the instrument's range of
error and would show overexposure. However, the record shows that the noise to which
Thompson was exposed was of very high frequency, predominantly 8000 hertz. At 8000 hertz,
type 2 sound level meters and dosimeters have an inherent error factor of 6.5 dBA.[[27]]
This means that a dosimeter containing a Type 2 sound level meter would have to read over
240% to show overexposure once the inherent error of the instrument at 8,000 hertz is
taken into account. Cf. 29 C.F.R. § 1910.95, Appendix A, Table A-1 (hearing conservation
standard) (entry for 96.3 dBA corresponds to dose of 240 percent). Thus, where the noise
is predominantly at 8,000 hertz, a dosimeter reading of 158.5%, the reading obtained for
Thompson, does not show overexposure within the accuracy limit of the instrument.
We therefore vacate citation items 1a(B) and (D), and 1b(B) and (D). Having found that
OSHA proved over-exposure to quasi-continuous noise by press operators LeBlanc, Melanson
and Sund--the employees involved in items 1a(A) and (C), and 1b(A) and (B)--we must now
determine whether the Secretary showed that Collier-Keyworth violated the standard by
failing to take required precautions against excessive noise exposure.
IV. Precautions Against Noise Exposure
The Secretary alleges in citation item 1a that Collier-Keyworth violated section
1910.95(a) by failing to enforce the use of hearing protection equipment. In item 1b, he
alleges that the company violated section 1910.95(b)(1) by failing to implement feasible
administrative or engineering controls to reduce noise exposures.[[28]]
A. Personal Protective Equipment--Subsection 1910.95(a)
Citation items 1a(A) and (C) concern the alleged failures by the three employees to wear
personal hearing protectors. Industrial hygienist Hart observed LeBlanc and Melanson
wearing earmuffs and Sund wearing Swedish wool earplugs during her inspection. Hart
testified, however, that she also observed the employees "at one time or
another" not wearing hearing protection. The Secretary relies on Hart's testimony
that she observed the employees without heating protection to support his allegation under
section 1910.95(a).
The evidence does not prove that Collier-Keyworth violated section 1910. 95(a). Under the
standard, employees may be exposed to noise levels less than 115 dBA for some period of
time without using protective equipment. Also, at various times the three employees were
subjected to noise levels less than 90 dBA, where no protection is required regardless of
the length of exposure. Thus, Hart's testimony that she observed the employees at times
without protection does not prove a violation of the standard. If anything, the evidence
that the employees were sometimes observed wearing hearing protection tends to show that
Collier-Keyworth complied with section 1910.95(a). We therefore vacate citation items
1a(A) and (C).
B. Engineering Controls--Subsection 1910.15(b)(1)
The Secretary alleges in citation item 1b(A) and (C) that Collier-Keyworth violated
section 1910.95(b)(1) by failing to implement feasible engineering controls on presses
2208, 2210, and 2216.[[29]] His expert witness on engineering controls, Dr. Barry,
proposed two basic noise reduction techniques he believed were feasible: enclosing the die
areas on the presses; and replacing the existing air ejection nozzles with quieter ones.
Each press forms metal parts by the force exerted by a rapidly descending die on sheet
steel in the bed of the press. Barry testified that there were two primary sources of
noise associated with the operation of a press: (1) noise from the impact of the die on
the sheet metal stock; and (2) noise from the air ejection nozzles used to expel the parts
from the press bed. Barry recommended isolating the press operators from these noise
sources by installing acoustical enclosures around the die areas of the presses.[[30]] He
testified that the enclosures would have to be designed "to minimize any operator
encumbrances and allow for ease of die change." The enclosures, in Barry's opinion,
should be made of sheet metal, with transparent plastic panels to permit visual
observation of the die area. Doors and openings should be tightly sealed, and the inside
of the enclosure should be lined with acoustically absorptive material to prevent sound
buildup. Barry believed that each press enclosure would cost $3,500 to $4,000 to design,
fabricate, and install, and that a reduction in noise level of 10 dBA could be achieved.
Barry had seen similar enclosures in use at another company's plant and believed those
enclosures achieved a 10 dBA reduction without inhibiting production.
The enclosures Barry recommended would enclose the air ejection nozzles as well as the die
impact area, and would therefore reduce noise from both sources. Barry also testified that
the air noise could be reduced even if the die areas were not enclosed. Either quieter
nozzles that were commercially available could replace the existing nozzles, or the
velocity of air from the existing nozzles could be reduced to lessen the noise. Barry
stated that the commercial nozzles would cost $5 to $20 each and would, in his opinion,
produce a significant reduction in the noise level.
Curtis Holmer, a noise control engineer who testified for Collier-Keyworth, did not
believe that enclosing the die areas of the presses would significantly reduce the impact
noise emanating from the presses. Holmer testified that enclosing the die area can
significantly reduce the noise from a press only when the force the press exerts is
considerably below its capacity. However, when a press is used at or near its capacity, as
the presses were at Collier-Keyworth, then most of the energy of the impact is transferred
from the die area to the frame of the press, and most of the noise the press produces
radiates from its frame instead of from the point of impact. Holmer therefore believed
that enclosing the die area alone, as recommended by Barry, would not reduce the noise
resulting from the impact of the die on the stock. The enclosures would reduce only the
air ejection noise, and Holmer thought this noise reduction would be on the order of 3 dBA
or less.
Chief Engineer Cochran testifed that die enclosures would severely restrict the
productivity of the presses by increasing the time necessary for the operators to perform
any duty requiring access to the die area. Cochran reviewed the production reports
prepared by the operators for a four-week period to determine how often they needed access
to the die area. Estimating that each instance of access would require 30 extra minutes if
the dies were enclosed, he calculated that the company would have lost 72 hours of
production over the four-week period, or about 950 hours for a year.[[31]] Since the
company had no excess press capacity, it would have to purchase a new press to maintain
its current level of production. According to Cochran, a new press would cost $55,000. A
plant addition to house the machine would cost an additional $18,000, and a new operator
would have to be hired to run the machine at a cost of $24,000 per year. Cochran also
noted that the data on which he based these estimates might under-state the number of
times the operators needed access to the dies because the operators might not record
situations that were now very easy to resolve, such as clearing out a piece of scrap from
the die area.
Regarding Barry's suggestion that the existing air ejection nozzles be replaced with
quieter ones, plant engineer English testified that the company had tried using quieter
nozzles in 1977 but that those nozzles reduced the air velocity below what was needed to
eject the parts from the press bed. Curtis Holmer explained that quiet nozzles obtain
their noise reduction by reducing the air velocity and by spreading out the air stream
over a larger area. However, for small parts such as Collier-Keyworth made, much of the
air from such nozzles would blow past the part and be ineffective in moving it.
In Sherwin-Williams, 11 BNA OSHC at 2110, 1984-85 CCH OSHD at p. 34,702, the Commission
stated what the Secretary must prove to show a violation of section 1910.95(b)(1):
To prove a violation, therefore, the Secretary must prove that proposed engineering and
administrative controls are both technologically and economically feasible. As the Ninth
Circuit recognized in Castle & Cooke, "realism and common sense should dictate
how the Secretary may meet his burden of providing substantial evidence of
feasibility." 692 F.2d at 650. After the Secretary proves that controls are
technologically feasible, the burden of producing evidence shifts to the employer, who may
raise the issue of economic feasibility and go forward with evidence of the cost of
controls and personal protective equipment. The burden of producing evidence then returns
to the Secretary, "who must establish that the benefit of the proposed engineering
controls justifies their relative cost in comparison to other abatement methods." Id.
The ultimate burden of persuasion on the feasibility issue nevertheless remains with the
Secretary.
The Secretary clearly did not prove the feasibility of reducing the air ejection noise by
installing quieter nozzles. Although quieter nozzles are commercially available,
Collier-Keyworth had tried such nozzles several years before the alleged violation and
found that the reduced velocity of air they produced provided insufficient force to eject
the parts from the die area. Thus, such nozzles would not accomplish their intended
purpose and would be technologically infeasible.
We also find that the Secretary failed to prove the feasibility of die enclosures. The
enclosures would produce a minimal benefit insufficient to justify their substantial cost.
The enclosures Barry recommended would surround the die areas of the presses and isolate
the operators from the noise produced by the impact of the die on the stock and the noise
from the air ejection nozzles. Barry believed that such enclosures could reduce noise
levels about 10 dBA. Collier-Keyworth's expert, Holmer, testified that the enclosures
would produce only about a 3 dBA reduction. In Holmer's view, the die enclosures would
only reduce the air ejection noise reaching the operators, and not the noise from the die
striking the stock.
We give considerable weight to Holmer's opinion. Holmer had lengthy experience in the
measurement and control of industrial noise and was a member of the lnstitute of Noise
Control Engineering, a national organization of competent noise control professionals. He
provided a reasoned explanation for his conclusion that die enclosures on Collier-
Keyworth's presses would not substantially reduce impact noise and we find his testimony
persuasive. Barry's opinion that enclosures could achieve a 10 dBA reduction is entitled
to much less weight than Holmer's. Barry's training was primarily in measuring the effects
of noise on the human ear rather than the analysis and reduction of industrial noise by
engineering means. Barry had not designed or implemented industrial noise controls and was
not a member of the Institute of Noise Control Engineering. Moreover, Barry's opinion was
based only on his belief that die enclosures at another company had achieved a 10 dBA
reduction. Holmer's testimony indicates, however, that the noise reduction produced by a
die enclosure depends on the degree of capacity at which the press is used. Thus,
achievement of a 10 dBA reduction at another company, in the absence of evidence of
similar conditions, is a tenuous basis for believing that Collier-Keyworth could obtain a
comparable reduction. We find that the die enclosures recommended by Barry would achieve a
reduction of about 3 dBA in the noise levels to which Collier-Keyworth's press operators
were subjected.
A reduction of 3 dBA is significant (see Continental Can Co., 76 OSAHRC 109/A2, 4 BNA OSHC
1541, 1543 n. 8, 1976-77 CCH OSHD (P) 21,009, p. 25,253 n. 8 (No. 3973, 1976)), but it
must be balanced against the costs of engineering controls and considered in light of
other protective methods. See Sherwin-WiIliams, 11 BNA OSHC at 2110, 1984-85 CCH OSHD at
p. 34,702. The other method that we consider here is the personal protective equipment
that Collier-Keyworth's employees now wear. Dr. Victor Hildyard, a medical doctor
specializing in diagnosis and treatment of diseases of the ear, testified that earplugs
and earmuffs of the type used by Collier-Keyworth's employees could reduce the noise
reaching the employee's inner ear by 30 dBA if worn properly. Even if loosely fitted, the
equipment would reduce noise levels by 10-15 dBA. Thus according to Dr. Hildyard, a noise
reduction of 10 dBA is readily achievable even if the performance of the equipment is far
less than ideal. The highest time- weighted average sound level to which
Collier-Keyworth's press operators was exposed was about 98 dBA.[[32]] Thus, if
engineering controls were not required at all, the personal protective equipment would
very likely meet Collier-Keyworth's obligation under section 1910.95(b) to "reduce
sound levels within the levels of the table." Yet, even if engineering controls were
installed, the employees would still have to wear the personal hearing protectors because
a 3 dBA reduction would not reduce noise to within Table G-16 limits. They would simply
not have to wear it for as long as they now must. Thus, installing die enclosures would
not eliminate the need for personal protective equipment but would only decrease the
amount of time employees must wear it.
The cost of the controls is, however, substantial. According to Barry, each enclosure
would cost $3,500 to $4,000 to design, fabricate, and install. Moreover, to maintain its
current level of production, Collier-Keyworth would have to purchase a new press for
$55,000, and would incur additional costs associated with the new press, including a die
enclosure for that press as well. The new press would add a noise source to
Collier-Keyworth's plant and could result in additional noise exposure for some employees.
On balance, we are not convinced that the benefits to be gained from the enclosures
justify these costs. We therefore find that the die enclosures recommended by Barry were
not shown to be feasible and will vacate citation items 1b(A) and (C).
Accordingly, we vacate citations item 1a(B) and (D), and 1b(B) and (D), which involve
employee exposure to impulse noise, unless the Secretary requests an opportunity within 15
days of this decision to rebut officially-noted documents with evidence of the Secretary's
intent in 1969. We vacate items 1a(A) and (C) because the Secretary failed to show that
employees were not wearing personal hearing protectors for the periods required. And we
vacate items 1b(A) and (C) because the Secretary failed to show that proposed engineering
controls were feasible. The judge's decision is therefore affirmed.
FOR THE COMMISSION
Ray H. Darling, Jr.
Executive Secretary
DATED: April 6, 1987
Appendix
1. The noise standard proposed by the ACGIH committee in 1968 stated in 1968 stated in
part:
Average Sound Pressure
A-Weighting
Duration of
Levels Of Octave Bands
Network of
Exposure per
with Center Frequencies
Sound Level
Day
of 500, 1000, and 2000 Hz
Meter
_______________________________________________________
dB
dBA
Hours
85
92
4 - 8
90
97
2 - 4
95
102
1 - 2
100
107
less than
1 hour
_______________________________________________________
These values apply to total time of exposure per working day regardless of whether this
is one continuous exposures but dies [sic] not apply to impact or impulsive type of
noises.
When the daily noise exposure is composed of two or more periods of noise exposure of
different levels, their combined effect should be considered, rather than the individual
effect of each. If the sum of the following fractions:
C1\T1 + C2\T2 + ........Cn\Tn
exceed unity, then, the mixed exposure should be considered to exceed the threshold limit
values[.] C1 indicates the total time of exposure at a specified noise level, and T1
indicates the total time of exposure permitted at that level.
The above limits do not apply to impulse or impact type pf noise. It is
recommended that exposure to this type of noise should not exceed 140 dB peak sound
pressure level.
Appendix 1 of Herbert H. Jones, "ACGIH's Proposed Threshold Limit Value for
Noise," 29 AM. Indus. Hygiene J. 537-40 (Nov. - Dec. 1968)(ACGIH).
2. A paper cited by both the Inter-Society Committee and the ACGIH Committee and that
proposed criteria for steady noise concluded with the following observation :
We have purposely omitted any discussion of impulse noise up to now, for very sound
reasons. We know very little about the effects of impulse noise on the ear. We have just
started an intensive study of the relations between impulse noise and TTS (temporary
threshold shifts, a form of hearing loss).
The problem does not lend itself to easy solution, for several reasons. Measuring impulse
noise is difficult to begin with, but not nearly as difficult to resolve as determining
the effect the middle ear muscles have on the transmission of impulsive noise across the
middle ear. Limited laboratory research indicates that the laws governing TTS from
exposure to steady noise (non-impulse) do not operate for impulsive noise exposure.
Actually, this should not be surprising, since the response of the basilar membrane to
steady noise and to impulse noise should be completely different.
For the present, we can only say that no one should be habitually exposed to impulse noise
of any considerable magnitude without the use of hearing conservation measures.
Our very limited knowledge of the effects of impulse noise prevents any meaningfui
discussion of impulsive-type noise exposure.
A. Glorig, W.D. Ward, & J. Nixon, "Damage Risk Criteria and Noise-Induced Hearing
Loss," 74 Archives of Otolaryngology 413, 423 (Oct. 1961), cited in I-S at 424 ref.
16; and ACGIH at 539 ref. 6 (article) and at 540 ref. 6 (proposed standard).
3. A later report by a subcommittee chaired by Dr. Glorig proposed criteria for hearing
conservation with the following caveat:
Our knowledge of the relations of hearing loss to noise-exposure permits us to propose
guidelines for establishing standards for preventing significant noise- induced hearing
loss in the majority of exposed persons. These recommended standards have been proposed by
the International Organization for Standardization. They are presented below in brief
modified form. They do not apply to exposure to impulsive noise but only to steady noise.
Subcommittee on Noise, Committee on Conservation of Hearing, Am. Acad. of Ophthalmology
and Otolaryngology, Guide for Conservation of Hearing in Noise 13 (1964) (emphasis in
original), cited in I-S at 424 ref. 9.
4. A 1966 publication of the American Industrial Hygiene Association reviewed the criteria
for recommended noise limits that had been proposed by various investigators up to that
time. While noting that there was little disagreement as to the levels of continuous noise
that were harmful, the publication went on to say:
Much more difficult will be the selection of mandatory protection levels for intermittent,
short duration, and impact noises . . . . Because there is still much to be learned about
the relationships between temporary and permanent threshold shifts the criteria for brief
exposures cannot be expected to have the same reliability as those for continuous
exposures. Until more is known about short-time exposures, the criteria should be treated
as temporary benchmarks and be used with considerable judgment.
Am. Indus. Hygiene Ass'n., Industrial Noise Manual, ch. 7, at 59-60 (2d ed. 1966), cited
in I-S at 424 refs. 3 & 13; and ACGIH at 540 ref. 3 (proposed standard).
5. A 1967 paper by Coles et al. summarized studies that had tried to assess damage risk
from impulse noise exposure. R. Coles, G. Garinther, D. Hodge, & C Rice, Criteria for
Assessing Hearing Damage Risk From Impulse-Noise Exposure, U.S. Army Tech. Memo.13-67
(Aug. 1967), cited in ACGIH at 539 ref. 12 (article).[[33]] These studies tended to seek
permissible exposure criteria in terms of factors unique to impulse noise. Several of the
studies demonstrated that exposure to 25-100 impulses in the 140-170 dB range at 6-30
impulses per minute could produce temporary threshold shifts ("TTS")[[34]] in a
significant number of exposed persons. The variations in the TTS's of people exposed to
such impulse noise was greater than among subjects exposed to steady-state noise,
indicating that some people may be particularly susceptible to impulse noise. Responses
were observed to vary depending on whether the noise reached the ear at normal or grazing
incidence; in some instances, for example, noise from a gun fired by a person near the
subject, which would reach the subject's ear at normal incidence, appeared more harmful
than noise from a gun fired by a subject himself, which would reach his ear at grazing
incidence. TTS's were greater for longer duration impulses of similar peak intensity, a
result probably attributable to the greater energy associated with the longer impulses.
The paper drew from the studies criteria for peak pressure level and duration limits that
would not produce an excessive risk of hearing loss. It concluded that impulses in the
155-160 dB peak intensity range were safe for a duration of about 10 milliseconds, with
higher intensity impulses permissible for shorter duration's and lower intensity impulses
permissible at longer duration's.
6. In a slightly later paper, the same authors noted that it was customary in proposing
damage risk criteria for steady-state noise to exclude impulse noise by implication rather
than by direct statement. R. Coles, G. Garinther, D. Hodge. and C. Rice, "Hazardous
Exposure to Impulse Noise," 43 J. Acous. Soc. 336 (1968), cited in ACGIH at 539 ref.
11 (article). After discussing risk factors associated with common amounts of exposure to
gunfire, the paper said, "the more industrial types of impulse-noise exposure as in
riveting, pile driving, drop forging, etc., may require a separate criterion or may be
treatable by steady-state noise criteria." Id. at 339. However, the authors
concluded:
[w]hether a more general continuity between impulse and steady-state noise criteria can
ever be achieved seems very uncertain in view of the evident differences in their ranges
of TTS and of opinion such as that of Kryter and Garinther that PTS from impulse noise may
follow a different pattern from PTS due to steady-state noise.
Id. at 343 (reference omitted).
7. Investigators attempted to determine the combined effect of impulse noise and
steady-state noise in only one cited study. A. Cohen, B. Kylin, and P. LaBenz, Temporary
Threshold Shifts in Hearing From Exposure to Combined Impact/Steady-State Noise
Conditions, 40 J. Acous. Soc. 1371 (1966), cited in ACGIH at 539 ref. 10 (article). An
experiment was conducted on 15 subjects, who were exposed to a variety of combinations of
impulse and steady-state noise. The study found that, under some circumstances, impulse
noise in the presence of continuous noise was less harmful to hearing than the impulse
noise alone. The authors concluded that this was due to the "acoustic reflex,"
which is a contraction of the middle ear muscles that attenuates the amount of sound
transmitted to the inner ear. If the acoustic reflex is activated before exposure to a
loud impulse, the inner ear receives protection from the impulse. Therefore, when the
subjects were exposed to steady noise that was loud enough to activate the acoustic
reflex, the impulse noise was not as damaging as it otherwise would have been.
8. The standard proposed by the Department of Labor under the Walsh-Healey Act on
September 20, 1968, at 33 Fed. Reg. 14259-60, stated:
§ 50-204.10 Occupational noise exposure.
(a) The maximum permissible steady (or equivalent) noise level in the working environment
shall not exceed 85 decibels. Every employer shall utilize every feasible engineering
method to control noise levels. Such methods of control include reducing the amount of
noise produced at the source, reducing the amount transmitted through the air, and
substituting quieter procedures or machinery.
(b) Where the noise is not steady the equivalent steady noise level is determined by the
following procedure: The duration over 1 week of each clearly distinguishable sound level
is located in column 1 of Table 1 following this paragraph (b) and the partial noise
exposure is read at the intersection of this row with the appropriate sound level column.
The partial noise exposures thus obtained are added arithmetically. The sum is the
composite noise exposure. The continuous noise exposure equivalent to the composite noise
exposure is then read from Table II next following Table 1. If the variations in noise
level involve maxima at intervals of 1 second or less it is to be considered steady. If
the intervals are more than one second and the duration of the maxima are less than 1
second each, maximum is to be considered as 1 second.
TABLE I.. Duration /Week
The table referred to above is not available in this format.
Please telephone the Review Commission Public Information Office, 202-5398, to request a
paper copy:; TTY: 202-606-5386; FAX: 202-606-5050; e-mail: lwhitsett@oshrc.gov
Table II
The table referred to above is not available in this format.
Please telephone the Review Commission Public Information Office, 202-5398, to request a
paper copy:; TTY: 202-606-5386; FAX: 202-606-5050; e-mail: lwhitsett@oshrc.gov
SECRETARY OF LABOR,
Complainant
v.
COLLIER-KEYWORTH CO.,
Respondent
OSHRC DOCKET NO. 80-2848
APPEARANCES:
Robert Yetman, Esq., for Complainant Douglas B. M. Ehlke, Esq., for Respondent
DECISION AND ORDER
This is a proceeding pursuant to the Occupational Safety & Health Act of 1970, as
amended (29 USC, sec. 651 et seq.) hereinafter called the Act. The Complainant alleges
that the Respondent has violated sec. 5(a)(2) of the Act (sec. 654) by not complying with
the Occupational Safety & Health standards.
The Respondent is a corporation engaged in the business of manufacturing chair mechanisms
and its business affects the commerce of the United States.
The Respondent's worksite at Gardner, Massachusetts, was inspected by the Occupational
Safety & Health Administration (hereinafter called OSHA) on or about April 9 - 18,
1980.
On or about April 28, 1980, the following Citation, together with Notice of Proposed
Penalty, was issued against the Respondent: Citation #1, Items 1a - c, the serious
violation of the standards at 29 CFR 1910.95(a), .95(b)(1), and .95(b)(3); respectively
Items 1a, b and c of Citation #1.
On May 16, 1980, the Respondent filed Notice of Contest to Items #1a-c of Citation #1 and
the penalty proposed therefor.
In his post-hearing Brief, the Complainant withdrew item 1(c).
The pertinent words of the standards and the Act are appended to this decision under
appropriate titles. The basic issue is whether or not the Respondent's employees were
exposed to noise exceeding the limits of Table C-16 of the standard at 29 CFR 1910.95(a).
SINCE THE HEARINGS WERE HELD ON MARCH 23-27, JUNE 16-19, DECEMBER 8-11 [ALL IN 1981] AND
MARCH 23 and 24, 1982, THE 1981 TRANSCRIPT WILL BE REFERRED TO BY MONTH AND PAGE NUMBER
[E.G., MARCH 225] AND THE 1982 TRANSCRIPT BY YEAR, MONTH, AND PAGE NUMBER BECAUSE SOME OF
THE TRANSCRIPT PAGES ARE NUMBERED THE SAME EVEN THOUGH THEY COVER DIFFERENT DATES.
It was a very long and hard-fought case, involving many scientific treatises and expert
testimony. Both attorneys are to be commended for their excellent preparation and the zeal
with which they tried the case.
PRELIMINARY
Unless otherwise indicated, the word "dosimeter" [as used herein] refers to the
Gen Rad 1954 type 2 instrument used in the April inspection of the Respondent's jobsite.
The dosimeter has an integrator that "counts" the sound waves that constitute
noise; and it has a 5dB rate of exchange as distinguished from a 3dB one. A
"decibel" is roughly understood as a unit for expressing the relative intensity
of sound. The integrator may be "slow" [a time constant of 1 second] or
"fast" [a time constant of 1/8th of a second]. The slow integrator is considered
to be less accurate than the fast in following the quick noise...Tr. June 1147-1150.
The jobsite was inspected in April of 1980. The machines cited punch presses [#'s 2208,
2209, 2210 on the second floor annex, #0352 on the 4th floor, and #2216 on the 2nd floor
of the steel warehouse] and two lathes [#6040 and #3E 3018, both in the torsion
department]. The sound levels were obtained through the use of a dosimeter operated by or
under the supervision of OSHA Industrial Hygienist Anne Hart.
In measuring sound for the purposes of Table G-16 of the standard at 29 CFR 1910.95(a) -
(b)(3), a dosimeter at slow response with a 5dB rate of exchange is used because the
standard mandates a "slow" response. The evidence indicated that a different
rate of exchange [e.g., 3dB] would not qualify as a "slow" response; but, on the
other hand, a different rate of exchange might be more accurate for certain types of
sound. One of the issues in the case was whether the 5dB rate of exchange would disclose
the true level of sound if fluctuating or impulse [impact] noise were also present.
"Exchange rate" is the relationship between noise level and duration. To
illustrate: a 5dB exchange rate means that the sound level can be increased by 5dB with
every halving of exposure duration.
There are two sets of dates on which sound measurements were taken by the Complainant:
those in April, to which OSHC Compliance Officers Goyda and Hart testified; and those in
September, to which sound expert Barry testified. The witness Rockwell took sound
measurements in February of 1981; and the witnesses Jones, Kamperman, Holmer, Kundert, and
Botsford apparently did not participate in actual measurements of the cited machines but
testified as sound experts.
IMPULSE NOISE
The case required considerable evidence of a highly technical nature involving sound level
meters, dosimeters, 3dB and 5dB rates of exchange, various kinds of noise, etc. A basic
issue concerned impulse noise.
Several questions about impulse [or impact] noise must be resolved:
What is it? Did it exist in the cited machines? Was it accurately measured by the
dosimeters used in the inspection? Should it have been included or excluded in the
dosimeter readout to determine compliance with Table G-16?
TESTIMONY
Goyda
The witness Goyda, who is an experienced and competent Compliance Officer, was a member of
the OSHA inspection party. He monitored the dosimeter testing in April of the employee,
Couture ... Exh. C-1. I was impressed with his competence and honesty. I find that he
accurately reported the readout registered by the dosimeter, as recorded in Exh. C-1.
Hart
The witness Hart, who is an experienced and competent Industrial Hygienist, was in charge
of the April inspection of the jobsite. She calibrated the dosimeters used, directed the
placing of dosimeters on employees, and recorded or supervised the recording of their
readouts ... Tr. June 672 - 685. I was impressed with her competence and honesty. I find
that she followed proper procedures in testing and that she accurately reported the
readouts registered by the dosimeters, as recorded in Exh. C1 - 5.
She testified that the testing instrument was a Gen Rad 1954 Type 2 dosimeter, slow
response, A weighted...Tr. June 730, 733. She said that impulse noise is not supposed to
be included in the dosimeter measurement because the reading will be distorted and will
inaccurately register higher ... Tr. June 768-770. She also testified that there was
impulse noise from press #0352...Tr. June 715, 716.
Exh. C-1 - 5 reflect that the sound levels recorded during the April inspection ranged
from 94 to 101.3dBA as related to Table G-16.
Barry
The expert Barry, who was called by the Complainant, was well-qualified ... Tr. March 319
- 324. Exh. C- 20. He testified that the effects of impulse noise are not supposed to be
excluded; and that Table G-16 has no relation to impulse noise and does not exclude
it...Tr. March 512, 513, June 913, 914, December 902. He emphatically stated that the
findings of Compliance Officer Hart were reliable with correction factors that would not
change her conclusions; and that the type dosimeter used in her inspection was a suitable
instrument for measuring noise levels to determine OSHA compliance...Tr. June 952-958. He
concluded that, even applying error factors, employees were still exposed to excessive
noise...Tr. December 984.
However, Barry also testified that the dosimeter has been a controversial instrument in
recent years...Tr. March 517, 518. He said that dosimeters tend to register higher
readings than actual noise levels; and that, for the sounds typical here, the reading
could be higher by 4 or 8 decibels...Tr. June 953, December 939, Exh. R-60. He also said
that the more impulse and the higher, the greater is the dosimeter's error...Tr. June
1008. He testified that a dosimeter's readout might be inaccurate due to the slow response
setting required by the standard because, where there are both steady and impulse noises,
the dosimeter distorts on the high side; and that the use of both fast and slow modes of
response would be better testing procedure...Tr. June 925-928, 933, December 909, 910,
917, 948. He suggested that, "to measure it really properly, the standard would have
to be rewritten."...Tr. June 927. It had been his opinion [as he wrote in the OSHA
Field Officer's Manual] that, where both continuous and impulse noise are present, the
proper way to determine compliance with Table G-16 is to use the fast mode setting and
record the reading between the impulses...Tr. June 922, 923, 1015-1019. He had also
authored an article in which he stated that the standard at 29 CFR 1910.95 "sets the
permissible exposure level for non-impulse noise."...Tr. June 920. He acknowledged
that he had said that Table G- 16 was intended primarily for non-impulse noise ... Tr.
December 904, 906, Exh. R-59, R-62.
As concerns the 3dB and 5dB rates of exchange, he agreed that the readout would differ
depending on which was used, resulting in a possible dosimeter overstatement inaccuracy of
100 - 200 percent...Tr. June 934 - 937. He had also recommended a change in the dosimeter
from a 5dB exchange rate to the use of a 3dB one "and making no differentiation
between the type of noises. In other words, integrate all noise as noise. And, use that
for determining compliance or non- compliance."...Tr. June 943. While that suggestion
could be explained as referring to possible ambiguities in the standard, it could also be
interpreted as a belief that the standard does exclude some noise; otherwise, why the need
to specify that all noise is included?
Barry's testimony also indicated that there was a discrepancy of several decibels between
the slow and fast modes when he measured the machines in question in his September visit
at the Respondent's jobsite...Tr. June 975 - 999, Exh. C-22. [On this point, the testimony
is germane to the difference between the slow and fast modes, if not on the merits of the
citation itself.] He also testified that, in that same visit, he found impulsive
components of noise in all the cited machines except one lathe ... Tr. June 913, 955.
Rockwell
The expert Rockwell, who was called by the Respondent, was well-qualified ... Tr. June
1027 - 1031, 1131 - 1146, Exh. R-22. He testified that impulse noise [which is less than 1
per second and fewer than 60 per minute] should be handled separately; and that it has
been OSHA policy since 1972 to exclude or edit out such noise in testing. He also quoted
an OSHA regional office and Chapter 4 of the OSHA Field Manual to the same effect...Tr.
June 1150 - 1154, 1291. He said that the type of dosimeter used in the April inspection
erroneously read out several decibels higher because of impulse noise that should have
been excluded...Tr. June 1159, 1160. He pointed out that recognized authorities took the
same position... Tr. June 1161 - 1169, Exh. R-23. He also testified about tests he had
conducted in the Respondent's plant in February, 1981, using both slow and fast response
dosimeters. The slow response one [the type used in the instant case] registered 5 - 14
decibels higher than the fast ... Tr June 1174 - 1207, Exh. R-25 - 33. He concluded that
the dosimeter overestimates exposure in "this" type of environment [the
Respondent's jobsite] by 10 - 12 decibels over the actual exposure level... Tr. June 1195
- 1202. He said that the use of a 5dB rate of exchange dosimeter resulted in inflated
exposure readings, grossly overestimated the true noise, and was an inaccurate instrument
for impulsive or rapidly fluctuating noise... Tr. June 1200 - 1202, 1209, 1234, 1236. He
specified errors of 10 - 15 decibels at each location that he tested... Tr. June 1287,
Exh. R-33. It was his opinion that the instrument used could not substantiate the
allegations, and that impact noise levels should be measured only with an impact meter or
an oscilloscope... Tr. June 1252, 1296, Exh. R- 35.
Holmer
The expert Holmer, who was called by the Respondent, was well-qualified ... Tr. June 1298
- 1310, 1479 - 1481, Exh. R-36. He testified that impulse noise should be eliminated in
determining compliance with the G-16 table... Tr. June 1456, 1457. 1515. He said that,
because of the difference between the 3dB and the 5dB exchange rates, the Gen Rad 1954
dosimeter used in the inspection would read higher than the actual noise level ... Tr.
June 1447, 1455, 1466, 1467. He said that such dosimeters invariably overestimate signals
fluctuating at the rate of 1 second or less; and that no dosimeter accurately records
impulse noise in the Table G-16 sense because the standard requires a 5dB exchange rate...
Tr. June 1441 - 1443, 1456. He also said that, although dosimeters read lower than theory
would project, and a Gen Rad 1954 dosimer does not overestimate as badly as an
"ideal" dosimeter would, it still overestimates by a factor of 10 whereas an
"ideal." one would overestimate by 12...Tr. June 1467, 1471.
Kundert
The expert, Kundert, who was called by the Complainant, was well-qualified. . . Tr.
December 778 - 780, Exh. C-27, C-28. He testified that the Gen Rad 1954 dosimeter was
designed specifically for testing against the OSHA standard, is excellent for that
purpose, and can process short signals even though most dosimeters cannot. Although he
said it was designed to measure both continuous and impulse noise, he acknowledged that it
cannot accurately measure very short impulses but tends to produce low readings. . . Tr.
December 795 - 797, 871 - 874. Concerning the 3dB and 5dB rates of exchange, he testified
that the dosimeter responds to impulsive sound as a 5dB instrument. . .Tr. December 863,
864. Concerning the question of whether Table G-16 is interpreted to include or exclude
impulse sound, he testified that the OSHA field guide says to exclude it as did ANSI
S-1.25. He concluded that, if impulse noise is to be excluded, the way to do it is by
reading between the pulses, as the witness Rockwell did.. Tr. December 888 - 890. He also
said that the authorities cited in Exh. R-23 did not support Rockwell's position but, on
the contrary, disagreed with it. . . Tr. December 798 - 803. Recalled by the Complainant
in rebuttal he said that, for the type of impulsive noise here, the sound level meter and
dosimeter give almost identical results; and that his in-court demonstration with the
dosimeter and sound level meter (measuring a continuous sequence of impulses) produced the
same results. . . Tr. 1982 March 1728 - 1730, 1871 - 1876.
Botsford
The well-qualified expert, Botsford, who was called by the Respondent, testified that the
Department of Labor had recommended the exclusion of impact noise from Table G-16, and
impact noise was not included in Table G-16. . . Tr. December 1038 - 1040, Exh. R-66.
His testimony tended to establish that impact noise could not be accurately measured by a
sound level meter but should be measured by an impact meter against
a limit of 140 decibels; while continuous noise should be measured against Table G-16,
using a time- weighted instrument with a 5 decibel exchange rate and then reading between
the impact peaks ... Tr. December 1076 - 1080. He said that the OSHA field manual
recommends this procedure ... Tr. December 1077, Exh. R-76.
Hildyard
The Respondent seemed to place great reliance on the testimony of Dr. Hildyard to the
effect that, although the advisory committee on OSHA standards made a final recommendation
of priority for administrative and engineering controls over personal protective devices,
the committee members had actually voted not to accord priority to administrative and
engineering controls over personal protective devices [such as ear plugs] ... Tr. March
565, 583. However, even if there had been no objection to such testimony [and the
Complainant did object to it], it would be given no weight because it violates the parol
evidence rule [See Evidence §1022, 1027 of 30 Am. Jur. 2nd; sec. 77.5 of Federal Trial
Handbook; and Del Prete v. Board of Selectmen, 351 Mass. 344]. The official record of the
advisory committee on OSHA standards --which said administrative and engineering controls
must be tried before personal protective equipment -- governs and not evidence tending to
contradict it. Accordingly, I am limiting Dr. Hildyard's testimony about the committee
vote to whatever bearing it may have on the Respondent's good faith.
Jones
The expert Jones, who was called in rebuttal by the Complainant, was a a well-qualified
industrial noise consultant. He testified that the sound level meter measures noise in the
slow response better than the fast and that there is no basis for editing out impulse
noise...Tr. 1982 March 1629 - 1639. However, he also stated that he agreed with the
statement that only steady noise is to be measured against Table G- 16 ... Tr. 1982 March
1695. Although his name also appeared on a document apparently stating that Table G-16
values do not apply to impulse noise, he testified that such use was unauthorized and did
not represent his opinion. . . Tr. 1982 March 1651 - 1658, 1668 - 1670. Because of his
sworn testimony to that effect, I do not place any reliability on that document as far as
it concerns any opinion by him.
Jones also testified that Botsford had written an article in which he said impulse noise
should be included in measurements of industrial noise. . . Tr. 1982 March 1637, 1638.
Kamperman
The expert Kamperman, who was called in rebuttal by the Complainant, was a well-qualified
industrial noise expert. He testified that the dosimeter is a very accurate instrument for
measuring noise in an industrial setting; that it always underestimates noise, and he had
found no dosimeter that read high. . . Tr. 1982 March 1902, 1947, 1984. He also said that
impulse noise should not be excluded from measurements and that industry custom is to
include it in computing noise for purposes of Table G-16. . . Tr. 1982 March 1913 - 1917.
He pointed out that if impulse noises are edited out of a punching operation, there would
be no noise left because they are all impulsive signals. . . Tr. 1982 March 1898, 1911. He
said that his field testing of the 1954 Gen Rad dosimeter and a sound level meter produced
approximately the same results, whether with or without impulse noise. . . Tr. 1982 March
1900, 1901. He also said that the fast response is not as good as the slow in determining
noise per Table G-16. . . Tr. 1982 March 1902. He concluded that he had never said that
impulse noise should only be measured in accordance with the 140dB peak, and had never
said that impulse noise should be excluded from measurements. . . Tr. 1982 March 1984,
1985.
However, when he was asked if he had said that "it is not possible for a simple
dosimeter to correctly compute the noise dose using a 5dB exchange rate for noises that
vary in levels of less than 10 seconds," his answer included statements that
"problems come because of the OSHA 5dB exchange rate. . . because the 5dB exchange
rate violates basic laws of physics". . . Tr. 1982 March 1960 - 1966. He also
testified that the dosimeter "has a hard time correctly measuring anything other than
steady random noise" and that he is "on the committee to revise this standard
now to make dosimeters capable of correctly measuring impulsive sound.". . . Tr. 1982
March 1945. He also conceded that there is "confusion" over the measurement of
impulsive noise in the industrial environment and that he had written an article stating
that the standard only addresses the measurement of continuous noise. . . Tr. 1982 March
1948, 1949, Ex. R-110. He also testified that he had made a written statement that, for
impulsive noise, "the dosimeter will always indicate a much higher dose that the
sound level meter" and that the disparity would be 100% or a difference of 5dB. . .
Tr. 1982 March 1953, 1954, 1968, 1970. While he also testified that this was an incorrect
interpretation of his view, he nevertheless conceded that he had told a seminar that
"dosimeters used in the noise environment typically found in metal fabricating
facilities would read between 5 and 13dB too high, two to six times the expected noise
dose relative to the OSHA 5 decibel exchange rate.". . . Tr. 1982 March 1953 - 1957,
1968-1970.
DISCUSSION
With very minor differences, the experts all seemed to be in general agreement that
impulse noise is a sound of brief duration that occurs less frequently than one a second
and less than 60 a minute; and includes such examples as hand clapping, dropping a book,
firing a rifle, the ram of a punch press, etc. It is also clear that all the cited
machines [with the possible exception of the lathes] had impulsive components in the
noise. . . Tr. March 311, June 913, 921, 955, 956, 1150, 1251.
As indicated above in this decision, the experts differed in their opinions on the
accuracy of the measurements by the dosimeter. Rockwell, Holmer, and Botsford were firm in
their conclusions that the dosimeter had to be inaccurate because of the standard's
requirements that only the slow response may be used.
Although Barry, Kundert, Jones and Kamperman concluded that the dosimeter readouts were
accurate, they did make many concessions [specified above] that tended to establish there
were distortions by the dosimeters used in the April inspection.
In my opinion, the weight of the evidence clearly establishes that the dosimeters used
were certain to overstate the employees' exposure to noise. I so find.
The most troublesome question is whether impulse noise should be included or excluded from
the dosimeter readout. The standard itself merely uses the words "noise" or
"sound" except for the word "continuous" in paragraph (b)(2). Table
G-16, with figures going only as high as 115, has a footnote: "Exposure to impulsive
or impact noise should not exceed 140dB peak sound pressure level". The standard at
.95(b) 1 - 3 clearly mandates that sound levels be "measured on the A scale...at slow
response". Table G-16 also specifies: "Sound level dBA slow response". The
Compliance Officer has no choice: the standard must be obeyed. The dilemma is that the
standard mandates the use of the slow response mode of testing, but the evidence
establishes beyond doubt that, when impulsive noise is present, the slow response mode
results in an inaccurate readout in excess of the true noise level.
Even if the use of the slow response dosimeter results in distorted readings, is the
question of compliance to be based on such figures? It is hard to believe that any branch
of government would intend such a result. Certainly a judicial forum could not condone any
decision based on inaccurate facts.
The Complainant has the burden of proving that the Respondent's employees were exposed to
noise that exceeded the amounts specified in Table G-16. In my opinion, that calls for the
Complainant to prove that there were actual and true noise levels in the amounts stated in
Table G-16, and not merely readout figures provided by the mandated slow response
dosimeter. I find that that is the Complainants burden of proof even if it means that the
Compliance Officer has to use two sets of instruments: one to comply with the mandate of
the OSHA standard and a second to satisfy the demands of proof and due process of law.
A third alternative, of course, is for some modification of the standard (or Table G-16)
in conformity with the most acceptable technology available [a need recognized by the
Complainant's very experienced expert, Barry... Tr. -June 927]. I strongly recommend such
modification because it is a scandalous situation when the various entities concerned with
safe working conditions -- OSHA, the employer and employees, the Complainant and the
Respondent, the attorneys, and the judicial forum itself -- are all at the mercy of a
system that practically guarantees controversy and uncertainty -- because even the experts
themselves are in almost total disagreement.
If the present state of the law requires the use of instruments in addition to any that
are mandated by the standard, or calls for measures to correct the readout figures, or
makes the Complainant's task more difficult in any way, that is unfortunate; but the
Complainant has the burden of proving its allegation.
On the question of the accuracy of the slow response dosimeter when impulse or impact
noise is present at the jobsite, there may be a conflict of testimony between the experts
for the Complainant and the experts for the Respondent. Assuming that all are equally
honest and equally well-qualified [and I find them so to be] has the Complainant carried
his burden of proof?
I find that the dosimeter's accuracy has not been established; in fact, quite to the
contrary, its inaccuracy was proven. The testimony of the Respondent's experts to that
effect was not shaken: and the Complainant's experts [Barry, Jones, Kundert. and
Kamperman] also made several statements tending to the same conclusion. The inspection
officer herself (Hart) also agreed that the dosimeter readout would be inaccurate when
impulse noise was included. In that state of the evidence, I find that the dosimeter's
accuracy was not proven.
On the question of whether to include or exclude impulse noise in determining compliance
with Table C-16: 1 find it should be excluded. In the first place, its inclusion was the
basic cause of the dosimeter's inaccuracy in the instant case. Secondly, I find that it
was the customary practice for OSHA to exclude impulse noise in determining the
possibility of noise exceeding the figures in Table G-16. The uncontradicted testimony of
the expert Rockwell was that it has been OSHA policy since 1972 to exclude such noise; and
that Chapter 4 of the OSHA Field Manual is to the same effect...Tr. June 1150 - 1154,
1291. Hart's testimony that impulse noise was not supposed to be included corroborates
that conclusion.
The Respondent has a constitutional right to be treated the same as any other employer
cited under the same standard. If the customary practice of OSHA was to exclude such
impulse noise, it should have been excluded in the instant case.
Lastly, I find that any reasonable interpretation of Table G-16 leads to the conclusion
that impulse noise must be excluded. An analysis of the standard can lead to no other
conclusion. We begin with the assumption that it was intended to have a workable standard
with accurate figures in Table G-16 -- and the standard should be interpreted to achieve
those ends. The standard clearly and explicitly states that the slow response mode must be
used -- but that mode cannot accurately measure impulse noise. The standard is so
ambiguous about impulse noise that (in my opinion) reasonable persons would agree that two
interpretations are possible: (1) that impulse noise should be included in the dosimeter
readout; or (2) it should be excluded. The first interpretation [including impulse noise]
results in an inaccurate readout. Consequently, the more reasonable conclusion is to
exclude impulse noise since that is the only interpretation that gives accurate figures in
the readout while still complying with the slow response mode, as mandated by the
standard. That is the only interpretation that gives a workable standard with accurate
figures in Table G-16.
In the final analysis, the Complainant has not proven its case whether impulse noise is
supposed to be included or excluded. If it should have been excluded, that was not done
here; and if it should have been included, it results in an inaccurate readout. In either
event, the dosimeter used was not a reliable instrument on which to base the citation.
The difference between the true sound level and the dosimeter's inaccurate readout was not
minor but amounted to at least several decibels. When the dosimeter's readout ranged from
94 to 101.3 decibels, an error of several decibels could easily bring the true figures to
those in compliance with Table G-16. While an error of several decibels might not be of
any significance if the dosimeter readout were greatly in excess of the figures in Table
G-16, it becomes of paramount importance when [as here] the readout ranges from 94 to
101.3 decibels.
Where the noise is so excessive that an error of several decibels in the dosimeter is
comparatively trivial, the inaccuracy becomes immaterial. For example, in the Frank Nutty
case [5 OSHC 1727], where the recorded noise was 8 times more than that permitted in Table
G-16, the Review Commission affirmed without review the decision of the Administrative Law
Judge that the Respondent had not complied with the noise standard concerned. [Although
the dosimeter was held to be adequate in that case, I find it easily distinguishable from
the instant case]. Here, where the alleged excessive noise is comparatively slight and the
dosimeter error comparatively great, it must be found that the Complainant has not proven
excessive noise.
Offers of Proof by the Complainant
Even assuming the admissibility of the evidence in the Complainant's various offers of
proof, the quantity and quality of evidence casting doubt on the reliability of the
dosimeter is not diminished. If the proffered evidence had been admitted, it would not
change my findings.
Barry's testimony of September inspection
In seeking to establish the admissibility of Barry's testimony concerning his September,
1980, visit to the jobsite, the Complainant offered the testimony of Compliance Officer
Goyda that the conditions prevailing at that time were similar to those of the official
inspection in April, 1980. The substance of Goyda's direct examination was that the
machines and the parts produced appeared to be the same on both dates and he observed no
difference in them ... Tr. March 29 - 31, 299 - 302. He took no measurements but described
the parts in fairly general terms. He testified that he heard the noise emitted by the
machines and it was "the same" on both dates ... Tr. March 303.
Cochran, the Respondent's chief engineer, testified that the punch presses used some 20 -
30 difference dies of varying weights, shapes, and thickness in producing 30 different
components or parts. The weights vary from 200 to one thousand pounds in sizes ranging
from 8 x 10 inches to 22 x 16 inches...Tr. March 103 - 108, 122. He said the manner in
which the machines are operated changes every day; and the number of parts and the length
of the run vary with the particular job...Tr. March 112 - 114, 171. That is also true of
the machine's number of strokes per minute...Tr. March 130, 149 - 151. He testified that
the parts made by machines 2208 - 2210 "are all different" and that the two
parts made on April 14th [the inspection date] were not like the two parts made on
September 15th [the date of Barry's visit] but were "4 absolutely different
parts" . . . Tr. March 287. He explained that, although the machines themselves were
identical, the operation was not "because it had a different tool in it and every
tool runs differently. . . not the same steel strip. . . a different width and fed a
different length.". . . Tr. March 289. He also pointed out that there would be
"a wide variation" in the noise because the gauge of the material is "one
factor that is involved in producing noise when that die hits the stock". . . Tr.
March 291, 292. He also testified that there were different sounds on the lathe on some
days. . . Tr. March 128.
Bergeron, the Respondent's assistant director of manufacturing, testified that dies may or
may not be changed frequently because it is a job shop. . . Tr. March 226 - 229.
There was no contradiction of the testimony of Cochran and Bergeron on the differences in
dies, parts, strokes, and length of run. Moreover, I was favorably impressed by the candor
and honesty of both witnesses; and both certainly were in positions to know about the
operations they described.
It was ruled that, on the basis of Goyda's testimony that conditions during the April and
September visits were similar, Barry's testimony about his September visit was technically
admissible; but both parties were alerted to the fact that it would be given very little
weight. . . Tr. March 303 - 307. My opinion was [and is] that in a matter as sensitive and
delicate as the determination of decibels of noise, more is required than Goyda's mere eye
and ear observation of the appearance and sound of machines and parts. The testimony of
Barry about his September visit was admitted because, technically, Goyda's testimony
furnished a foundation of similarity. I have given it very little weight because,
substantively, Cochran's uncontradicted testimony established that the difference in dies,
parts, strokes, and lengths of run may well have resulted in different noise levels.
REVIEW COMMISSION
In view of my findings concerning the inaccuracy of the dosimeter, I have not reached
items 1(b) and 1(c) of Citation #1. I purposely have not made alternative findings because
it seems to me to be of over-riding importance for the Review Commission to clear up the
uncertainties arising out of the possible interpretations to which the standard at 29 CFR
1910.95 is susceptible. I respectfully request that my decision be reviewed to that end.
[As cited above, I am aware of the Frank Nutty case interpreting a virtually identical
noise standard. However, I think that decision is not only distinguishable in several
aspects from the instant case but, of great importance, the point raised here was not
discussed there.]
FINDINGS OF FACT
Having heard the testimony, observed the witnesses, and examined the exhibits, the
following Findings of Fact are made:
1. At all times concerned, the Respondent regularly received, handled or worked with goods
which had moved across state lines.
2. As concerns Items #1(a) of Citation #1, the dosimeter used in the inspection did not
accurately record the true sound levels.
3. The true sound levels did not exceed the figures of Table G-16.
4 The sound levels exceeded those shown in Table G-16 when measured on the A scale of a
standard sound level meter at slow response.
CONCLUSIONS OF LAW
1. At all times concerned, the Respondent was an employer engaged in a business affecting
commerce within the meaning of the Act; and the Occupational Safety & Health Review
Commission has jurisdiction over the subject matter and the parties.
2. The Complainant has not sustained the burden of proving the Respondent violated the
standard at 29 CFR 1910.95(a).
ORDER
The whole record having been considered, it is ordered that Citation #1, and the penalty
proposed therefor, be vacated.
SO ORDERED.
FOSTER FURCOLO
JUDGE, OSHRC
Dated:June 28, 1982
Boston, Massachusetts
APPENDIX
THE ACT
Section 654 [section 5(a)(2)] Employer "...shall
comply with occupational safety and health standards..."
Section 666 [section 17(b)] "...employer who has
received a citation for a serious violation ... of this Act...shall be assessed a civil
penalty of up to $1,000 for
each
such violation."
Section 666 [section 17(k)] "...a serious violation
shall be deemed to exist...if there is a substantial probability that death or serious
physical harm could result ...
unless
the employer did not, and could not...know of the presence of the violation."
THE STANDARDS
29 CFR 1910.95(a) - (b)(3);
§ 1910.95 Occupational noise exposure.
(a) Protection against the effects of noise exposure shall be provided when the sound
levels exceed those shown in Table G-16 when measured on the A scale of a standard sound
level meter at slow response.
(b)(1) When employees are subjected to sound exceeding those listed in Table G-16,
feasible administrative or engineering controls shall be utilized. If such controls fail
to reduce sound levels within the levels of Table G-16, personal protective equipment
shall be provided and used to reduce sound levels within the levels of the table.
(2) If the variations in noise level involve maxima at intervals of 1 second or less, it
is to be considered continuous.
(3) In all cases where the sound levels exceed the values shown herein, a continuing,
effective hearing conservation program shall be administered.
TABLE G-16 - PERMISSIBLE NOISE EXPUSURES[[1]]
Duration per day, hours
Sound
level dBA slow
response
8 ..................................................................................
90
6 ................................................................................
92
4 ................................................................................
95
3 ................................................................................
97
2 ..............................................................................
100
1-1/2 ......................................................................
102
1 .............................................................................
105
1/2 ...........................................................................
110
1/4 or less ...............................................................
115
[[1]] When the daily noise exposure is composed of two or more periods of noise exposure
of different levels, their combined effect should be considered, rather than the
individual effect of each. If the sum of the following fractions: C1/T + C2/T2 Cn/Tn
exceeds unity, then, the mixed exposure should be considered to exceed the limit value. Cn
indicates the total time of exposure at a specified noise level, and Tn indicates the
total time of exposure permitted at that level.
Exposure to impulsive or impact noise should not exceed 140 dB peak sound pressure level.
FOOTNOTES:
However, Ward noted that there was evidence in 1969 that impact noise should produce
hearing loss, but that the addition of impulse noise to a steady noise reduced the effect
of noise on hearing, and in other cases, enhanced the effect; in other cases there was no
effect (II, p.379).
[[1]] The standard is quoted in its entirety except for provisions dealing with
determining noise levels by octave band analysis, a measurement technique not involved in
this case.
[[2]] This problem was noted early in the Commission's experience with the noise
standard. See Weyerhaeuser Co., 74 OSAHRC 57/F4, 2 BNA OSHC 1152, 1153-54, 1974-75 CCH
OSHD (P) 18,468, pp. 22,485-86 (No. 2116, 1974) (lead opinion); Sun Shipbuilding &
Drydock Co., 74 OSAHRC 61/A2, 2 BNA, OSHC 1181, 1182-83, CCH OSHD (P) 18,537 (No. 268,
1974) (lead and concurring opinions); Weyerhaeuser Co., 77 OSAHRC 9/A2, 4 BNA OSHC 1972,
1974-75, 1976-77 CCH OSHD(P) 21,465, pp. 25,748-49 (No. 1231, 1977), aff'd in pertinent
part, sub nom. Noblecraft Industries, Inc. v. Secretary, 614 F.2d 199 (9th Cir. 1980).
[[3]] Collier-Keyworth argues that the use of a dosimeter is inherently inconsistent with
the standard, which specifies that noise levels are to be measured with a standard sound
level meter. As we have explained, the dosimeter itself contains the circuitry of a
standard sound level meter. It also contains other circuitry, but the other circuitry only
performs automatically calculations that would otherwise have to be done manually. Thus,
the dosimeter does precisely what the standard requires: measures sound levels with a
standard sound level meter and performs the calculations required by the cumulation
formula. Whether it performs those functions with sufficient accuracy is another question,
which we will address later. For now, we note only that the use of a dosimeter is
consistent with the standard, and reflect Collier-Keyworth's contrary arguement Love Box
Co., 76 OSAHRC 45/05 4 BNA OSHC 1138, 1140 & n.2 1975-76 CCH OSHD ¶20,588 p. 24,628
& n2 (No.6286,1976).
[[4]] In 1981, section 1910.95 (b) (3) was replaced with a new standard, known as the
"hearing conservation standard" or "hearing conservation amendment,
"which lists in detail the requirements a hearing conservation program must have. 46
Fed.Reg 4078 (Jan. 16, 1981), now codified at 29 C. F. R. § 1910.95 (c)-(p). The hearing
conservation standard requires an employer to implement a hearing conservation program
wherever employee noise exposures equal or exceed an eight hour time-weighted average
level of 85 dBA. 29 C. F. R. §1910.95 (c) (1). It also provides that, in determining
whether this limit is exceeded, "[a]ll continuous,
intermittent and impulsive sound levels from 80 decibels to 130 decibels should be
integrated into the noise measurements." 29 C. F. R. § 1910.95 (d) (2) (i). Thus,
impulse noise is explicitly included in the hearing conservation standard. However, in
promulgating the hearing conservation standard, the Secretary did not purport to amend any
provision of the old standard except subsection.(b) (2) The hearing conservation standard
therefore does not affect whether impulse noise is included under the standard involved in
this case, section 1910.95 (a)-(b) (2), which require administrative and engineering noise
controls and personal protective equipment.
[[5]] The Secretary's expert witness, Dr. Burton Jaffe, testified that noise is a
"mechanical transfer of energy that really shakes the hair cells and damage
them".The manner in which this testimony is summarized in the Secretary's brief
echoes what has become known as the "equal energy rule," a theory that equal
amounts of noise energy are equally harmful regardless of their form or duration. This
theory was discussed at length in the preamble to the Secretary's new hearing conservation
standard and expressly applied to impulse noise. See 46 Fed. Reg. at 4096. Its application
to impulse noise seems to have been upheld on the basis of the rulemaking record compiled
by OSHA to support the hearing conservation standard. See .Forging Industry Ass'n V.
Secretary of Labor, 773 F.2d 1436, 1451 (4th Cir. 1985) (en blanc).
[[6]] The Secretary attempts on the basis of a witness's testimony to reconcile Table G-16
with the 140 dB provision. We shall consider this testimony after have completed our
review of the text of the standard. See note 12 below.
[[7]] When the original version of the standard was published by the Labor Department's
Bureau of Labor Standards under the Walsh-Healey Government Contracts Act, 41 U. S.C. §
35-45, this provision was set in the same size type as other text and placed after the
footnote to the table. See 34 Fed. Reg. 7949 (1969) and 35 Fed. Reg. 1015 (1970)
(corrections to standard). When the standard was adopted and reprinted under the OSH Act
in 1971, the Secretary did not support to--and was in any event not. empowered to--make
any substantive change in it. Yet, the 140 dB provision was then printed in the same small
type as the footnote to the table, apparently because a typesetter mistook it to be a
continuation of the footnote to the table immediately above. 36 Fed. Reg. 10466, 10513
(1971). We are confirmed in this impression by four Labor Department documents. The Labor
Department's own edition of OSHA standards, I General Industry Standards and
Interpretations 144 (OSHA No. 2077, .1984), prints the 140 dB impulse noise provision in,
and in the same size type as, the text. The 140 db provision is still part of the text of
the original Walsh-Healey standard, 41 C.F.R. § 50- 204.10. A Labor Department bulletin
interpreting the Walsh-Healey standard characterized the provision as "[t]he last
sentence in paragraph (d) of section 50-204.10 . . . . " Bureau of Labor Standards,
U.S. Dept. of Labor, Bulletin 334, Guidelines to the Department of Labor's Occupational
Noise Standards for Federal Supply Contracts, 4 (Dec. 4, 1970). Finally, the corresponding
provision in OSHA's noise standard for the construction industry-- which adopted at about
the same time as the original general industry standard (see 36 Fed. Reg. 7340, 7348
(1971))--was printed in a separate subsection, now codified as 29 C.F.R. § 1926.52(e)
[[8]] That provision states in part that "[w]hen an agency decision rests on official
notice of a material fact not appearing in the evidence of the record, a party is
entitled, on timely request, to an opportunity to show the contrary."
[[9]] The record contains various terms used to describe non-impulsive noise, such as
steady noise, continuous noise, steady-state noise, and intermittent noise. Except for
intermittent noise, these terms suggest noise that is constant in intensity over a
relatively long period of time. Intermittent noise varies in intensity, but not as rapidly
as impulse noise. For example, noise from a machine that is alternately on and off for
several seconds at a time would be classified as intermittent noise.
[[10]] Even in 1981, when the Secretary promulgated the hearing conservation amendment to
the noise standard, there was a relative dearth of information on impulse noise. The
Secretary noted: "In contrast to the studies of continuous noise mentioned above,
dose-response relationships for impulse noise are not so easily defined." 46 Fed.
Reg. at 4096.
ACGIH, "Threshold Limit Values of Physical Agents" (1969), reprinted in National
Safety Council, Fundamentals of Industrial Hygiene, Appendix A, pp.739-41 (1971).
Collier-Keyworth introduced as Exhibit R-101 the 1971 version of the ACGIH standard, which
appears to be identical..
[[12]] See also a chapter by Jones, "Standards and Threshold Limit Values for
Noise," in National Safety Council, Industrial Noise and Hearing Conservation ch. 11,
p. 309 (Olishifski & Harford eds. 1975)(ACGIH limits "incorporated in"
Walsh-Healy standard). That the ACGIH standard substantially influenced the drafters of
the Walsh-Healy standard leads the Secretary to rely heavily on testimony by Jones,
who was chairman of the ACGIH committee, that the table in the ACGIH standard
corresponding to Table G-16 "would include anything that the sound level meter would
respond to, be it a continuous[,] impact [or] impulsive noise." Jones further
testified that the 140 dB impulse noise provision was intended to be an additional
restriction on impulse noise, included because of the possibility that high intensity
impulses could be harmful even if the limits in the table were not exceeded. The Secretary
states that Jones "was, in effect, the author of the [140 dB impulse noise]
provision" because the limits in the table adopted by Jones's ACGIH Committee were
"issued in virtually identical form by the Department of Labor as a standard under
the Walsh- Healey Act. . . . ." We are unable to credit this part of Jones's
testimony because the ACGIH standard expressly stated that the exposure limits in its
table do not apply to impulse noise. We therefore disagree with the argument in the
Secretary's brief that this part of Jones's testimony is a reliable guide to the intent of
the drafters of the Walsh-Healey standard.
[[13]] The bulletin was revised on June 8, 1971, after the Walsh-Healey standard was
adopted under the OSH Act. The 1971 version was introduced into evidence.
[[14]] A passage written by Dr. Van Atta in Industrial Noise and Hearing Conservation, n.
12 above, at 322, also suggests this. The passage, which was read into the record, states:
This regulation provides for a basic level of 90 dBA for continuous noise exposure with a
tradeoff of 5 dBA for each halving of the noise exposure time. This includes a rough
allowance for interruptions of noise exposure. Impact noises must be limited to less than
140 dB peak sound pressure level.
It is important to note that this is a double requirement. For example, in a power-press
department, it is necessary that both the instantaneous peaks of the impact noises arising
out of the operation of large presses be below 140 dB and that the continuous ambient
background noise be below 90 dBA. [Emphasis added.]
[[15]] J Barry, "Problems in Enforcement of the Occupational Noise Standard,"
in Proceedings of Noise-Con 79, Machinery Noise Control, 11 (Sullivan & Crocker eds.
1979). At the hearing in this case, Dr. Barry first testified that Table G-16 "has no
relation in impulse noise." He later stated, however, that the standard did intend
for impulse noise to be included in dosage calculations.
[[16]] The chapter is printed in Occup. Safety and Health Admin., U. S. Dep't of Labor, VI
OSHA No. 3058, Industrial HygieneField Operations Manual (1980), and in CCH Employ, S.
& H. Guide, Edition No. 419 (May 24, 1979).
[[17]] At the hearing in this case, Dr. Barry stated that he recommended the use of fast
response in this instruction to enable the inspector to analyze the components of the
noise to assist in evaluating the feasibility of engineering controls. (Fast response,
like slow response, is a setting on a sound level meter. For the moment it is enough to
observe that where impulse noises are closely spaced, fast response is more accurate than
slow response in displaying the true background noise level.) When the Secretary
promulgated the hearing conservation amendment in 1981, he said that this IHFOM provision
"is clearly at variance with the present standard and is being deleted." 46 Fed.
Reg. 4078, 4137 & n. 11 (Jan. 16, 1981). If, as Dr. Barry stated, the purpose of the
provision was to assist inspectors to evaluate the feasibility of engineering controls,
there would have been no need for the Secretary to disavow it in this manner. In sum, we
read the instruction as OSHA did-to signify that impulse noise was not to be included in
determining whether employee exposure exceeds Table G-16 levels.
The Secretary also claims that the prescription of slow response in the standard is
inconsistent with any intent to exclude impulse noise from Table G- 16. We are unconvinced
of any logical inconsistency here. The ACGIH standard--from which the Secretary
acknowledges the drafters of the Walsh- Healey standard drew heavily--both prescribed slow
response and excluded impulse noise. The same is true of the noise standard proposed by
the Secretary in 1974. See 89 Fed. Red 37773, 37775 (Oct. 24, 1974), proposing new section
1910.95 (c) (1) (ii).
[[18]] Turner involved three presses in the same room. One stroked at a rate of 27 per
minute, and a second at 33 to 38 strokes per minute. 4 BNA OSHC at 1556,1976-77 CCH OSHD
at pp. 25,273-4. Thus, these two presses alone would produce 60 or more noise impulses per
minute, i.e., continuous noise.
[[19]] Collier-Keyworth occasionally alludes to this point in a confusing fashion,
speaking of dosimeters having an "effective exchange rate of 3 decibels. A
dosimeter set to employ a 3 decibel exchange rate would register the same sound levels as
would one set to employ a 5 decibel exchange rate. It would record a higher dosage,
however, because the lower exchange rate shortens permissible duration's. Yet,
Collier-Keyworth does not argue that OSHA set its dosimeters here to employ a 3 decibel
exchange rate. Instead, it maintains, based on the testimony of expert witnesses, that in
impulsive noise environments dosimeters set to use a 5 decibel exchange rate and slow
response will so overcount "true noise levels" as to approximate the results of
employing a 3 decibel exchange rate with fast response. Collier-Keyworth's argument rests
on the assumption that under Table G-16 sound levels must be measured with a fast response
instrument. We will discuss the validity of this assumption in the text below.
[[20]] This effect is illustrated by Ex. R-26, which contains several strip chart
recordings made by Rockwell, and by C-22L, a strip chart recording made by Barry. One
recording in Ex. R-26 shows noise patterns for a power press operating at 100 strokes per
minute. Because the peaks are less than one second apart, the noise is quasi-continuous.
With the sound level meter set for fast response, which corresponds to in integration time
of an eighth of a second, the individual impulses are readily visible and have peak
intensities of 108-109 dBA superimposed on a background of about 99 dBA. On slow response,
however, the noise appears relatively continuous at a level of 104-105 dBA. Thus, compared
to fast response, the sound level meter at slow response reads higher troughs but lower
peaks, that is, the individual impulses appear to be of longer duration but lower peak
intensity.
The reason for the difference is best explained by discussing the behavior of the needle
of a sound level meter: At slow response, the needle does not have time to return to the
continuous, background noise level before the next impulse comes along and caused it to
swing back up. For example, in Ex. C-22L,the sound peaks are about two to three seconds
apart, and hence much farther apart than in Ex R-26. The noise levels indicated by slow
response are still different from that of fast response but not as different as in Ex.
R-26, where noise peaks only six-tenths of a second apart gave the needle little time to
swing back before the next impulse arrives.
[[21]] Its argument is echoed in the observation of one dosimeter manufacturer that
"[i]t is the requirement of a slow response time constant in a dosimeter that causes
a dosimeter to appear to read high." Ex. R-24, statement by Quest Electronics.
[[22]] See American Mining Congress v. Marshall, 671 F.2d 1251, 1255-7 (10th Cir. 1982)
(discussing whether measuring method prescribed by mine health regulation is arbitrary,
capricious, or an abuse of discretion" within the meaning of the Administrative
Procedure Act).
[[23]] The brief of the Chocolate Manufacturers Association, which the Commission
permitted to appear on review as an amicus curiae, argues that dosimeters generally are
unreliable. Attached to its brief are studies by Dr. Paul Hess of Hershey Foods that argue
in support of this thesis and that criticize OSHA's evaluation of Dr. Hess's studies in
OSHA's preamble to revisions in 1983 of the hearing conservation standard. The Chocolate
Manufacturers Association also asks the Commission to take official notice of statements
in OSHA's Industrial Hygiene Technical Manual, p. B-47 (March 30, 1984)("the
IHTM"), reprinted in CCH Employ. S.& H. Guide, Extra Edition No. 680 (May 24,
1984), and in 2 BNA Occup. S.& H. Rep. 77:8001, 77:8925 (June 14, 1984). The Secretary
of labor objects to the Chocolate Manufacturers Association's brief, arguing that it
improperly introduces evidence. We deferred ruling on this motion and on the taking of
official notice of the IHTM material.
We take official notice of the IHTM but we are not persuaded that accepting its statements
as true mandates a result here. The portion of the IHTM relied on by the Chocolate
Manufacturers Association warns OSHA field personnel that "[s]hort-duration pulses
with a low repetition rate may be completely eliminated from the dosimeter readings simply
because the averaging circuits in the instruments cannot respond fast enough to the change
in level." However, we understand this passage to mean that dosimeters sometimes
undercount the noise level when certain impulses are present; moreover, if "low
repetition rate" refers to impulses more than one second apart, then the supposed
inaccuracy is irrelevant because we hold that such impulses may not be counted at all.
Another passage relied on by the amicus states that "[c]onversely, pulses with a
higher repetition rate may be overestimated by the dosimeter because the averaging
circuits will build up to the high level but will not have time to drop back down between
the pulses." We are puzzled by this passage, for it could be read to complain of the
slow response mode mandated by OSHA's own standard. In any event,if it refers to impulses
more than one second apart, it is irrelevant for the reasons we have already stated. And
if it refers to impulses less than one second apart, then it is also irrelevant because
under subsection (b)(2), the dosimeter does not have to drop back down between impulses at
all. Thus, we are not persuaded that the IHTM requires rejection of the dosimeter readings
here.
On the other hand, we grant the Secretary's motion to strike those portions of the
Chocolate Manufacturers Association brief that introduces the studies of Dr. Hess. We
decline to take official notice of this material. The material attached by the amicus to
its review brief is largely evidentiary, consisting of papers and studies by Dr. Hess
challenging the accuracy of dosimeters generally. As the Secretary argues, however, the
author of this material has not been subjected cross- examination and the Secretary's
counsel has had no opportunity to evaluate, impeach or rebut his studies. Thus, if this
new material were to be considered, a remand to Judge Furcolo would be in order. Yet, this
reopening of the record would be on the implied invitation of an amicus, not a party. In
these circumstances, we adhere to our rule against the admission of evidentiary materials
in review briefs. E.g., Anoplate Corp., 86 OSAHRC , 12 BNA OSHC 1628, 1683, n.6, 1986 CCH
OSHD (P) 27,519, pp. 35,681-2 n. 6 (No. 80-4109, 1986).
[[24]] Collier-Keyworth points out that in cross-examination Hart testified she did not
know the "strokes per minute" for the presses and suggests that this casts a
doubt on her testimony that she measured the speed of the presses. However, Hart's
testimony that she did not know the "strokes per minute" does not contradict her
unequivocal testimony that she timed the presses and found that the time between strokes
was less than one second. Under the standard, the noise is deemed continuous if the time
between strokes is less than one second and, once this is known, it is not necessary to
determine the exact time between strokes or the exact stroke rate.
[[25]] The strip chart recordings of noise levels made by Barry and Rockwell show noise
levels in the vicinity of the presses ranging from 95 to 105 dBA. Although these
measurements were made on different days than Hart's, they lend credence to Hart's
measurements indicating that the sound levels near the presses were typically in this
range.
[[26]] See Table 2 of Field Service Memorandum No. 11, in Appendix B, p. B-36 of the IHTM,
note 23 above. Cf. 29 C.F.R. § 1910.95, Appendix A, Table A-1 (hearing conservation
amendment)(entry for 91.9 dBA corresponds to dose of 130 percent).
[[27]] The error factors for Type 2 sound level meters are found in ANSI S1.4-1971,
"Specification for Sound Level Meters," at 11, Table 3. Some of the information
in that table, including the error factor at 8000 hertz, was included in the papers Dr.
Barry presented at Purdue University, which appears in the record as Exhibit R-62. OSHA
applied that information to Type 2 dosimeters in its IHTM. See Table 1 of Field Service
Memorandum No. 12, in Appendix B, pp. B-44--8-45 of the IHTM, note 23 above.
[[28]] Because he vacated all citation items on finding that the standard excluded impulse
noise, Judge Furcolo did not make findings on the merits. Normally, we would remand to him
for such findings. However, in view of the age of the case, we will make our own findings.
[[29]] The Secretary did not attempt to show that administrative controls for these
machines were feasible.
[[30]] Barry believed that erecting acoustical enclosures entirely around the presses
would be impractical due to space limitations and production demands.
[[31]] The dies for each press were changed an average of about once per day. Some of
Collier- Keyworth's dies weighed as much as 1,000 pounds and had to be changed using a
chain hoist. When the chain hoist was used, the die could swing into the enclosure and
damage it. Barry testified that this could be avoided if the operator was careful. Holmer
testified, however, that another company experienced severe damage to similar enclosures
after 14 to 20 die changes. Holmer also estimated that enclosures would add 20 to 40
minutes to the time required for a die change.
[[32]] The highest dosimeter reading the Secretary obtained for any of the press
operators was 305%. This is equivalent to an eight-hour time-weighted average exposure of
98 dBA. See section 1910.95, Appendix A, Table A-1.
[[33]] Most of the studies relied on in the paper were performed with gunshot noise,
but the authors considered the information sufficiently general to be extended to other
types of impulse noise.
[[34]] Threshold shift is a measure of hearing loss. A person's hearing threshold is the
lowest sound level in decibels that person can detect. If the person suffers hearing loss,
his threshold increases, i.e., he can no longer hear decibel levels as low as he
previously could. The number of decibels by which his threshold increases is his threshold
shift. A permanent hearing loss is referred to as a permanent threshold shift or PTS.
Short exposures to high noise levels can cause a temporary hearing loss, or temporary
threshold shift. When a person suffers a temporary threshold shift, his hearing recovers
after the exposure to high noise levels ceases. However, repeated exposures sufficient to
cause temporary threshold shifts can lead to a permanent threshold shift. Therefore, to
test whether noise exposures give rise to the possibility of permanent hearing loss,
scientists measure temporary threshold shifts in exposed individuals. If an exposure
produces measurable temporary threshold shifts, repetitive exposures of the same magnitude
will eventually cause permanent threshold shifts. See 46 Fed. Reg. 4078, 4080 (1981)
(preamble to hearing conservation amendment).